:LULQJ'LDJUDPV
6L86(
3DUW$SSHQGL[
)747$9-8')747$9-8$
0140A00500A
NOTES:
1. PLACE RED WIRES ON 208 V TERMINAL OF 2-TRANSFORMER
(TR1/TR2) FOR 208 VAC OPERATION.
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE
USED WHEN SERVICING.
3. IF ANY OF THE ORIGINAL WIRES AS SUPPLIED WITH THIS UNIT
MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING
MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105˚C.
USE COPPER CONDUCTORS ONLY.
4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFIRM TO
N.E.C AND LOCAL CODES.
5. DISCARD CONNECTOR PL1 WHEN INSTALLING OPTIONAL HEAT
KIT.
6. REMOVE SHORT RED CIRCUITING WIRE AND PUT AUX ALARM
SWITCH WHEN INSTALLING AUX ALARM SWITCH.
7. USE N.E.C CLASS 2 WIRE.
INTEGRATED CONTROL:
POWER/HEATER KIT/
DISCONNECT SWITCH
CONNECTOR
PL1, PL2
COMPONENT CODES:
F1U, F2U
TR1, TR2
TRANSFORMER
FUSE LINK
COLOR CODES:
BL - BLUE
RD - RED
YL - YELLOW
OR - ORANGE
BK - BLACK
GY - GREY
BR - BROWN
GR - GREEN
WH - WHITE
PU - PURPLE
LOW VOLTAGE
LOW VOLTAGE FIELD
HIGH VOLTAGE
HIGH VOLTAGE FIELD
JUNCTION
TERMINAL
PLUG CONNECTION
EQUIPMENT GND
FIELD GROUND
X1A
X3A
X38A
BS1
X12A
X13A
HAP
X8A
INDOOR UNIT PCB
THERMISTOR
(HEAT EXCHANGER 1,2)
MPU
MULTI
TENANT
(OPTION)
EEV COIL
M
K1R
K3R
TB6
TB8
K2R
HEATER KIT
OUTPUT
LEARN
PS
TB5
TB4
(ACC-OUT)
RELAY OUT
4
3
6
5
9
8
7
10
11
12
RD
BK
RD
BK
WH
BR
BL
BL
RD
FLASH
WRITER
OR
GY
RD
YL
BK
PU
YL
(SEE NOTE 5)
TO
HEATER KIT
BK
GR
GROUND LUG
CONNECTION DISABLED
(SEE NOTE 4)
24VAC
INSTALLING AUX ALARM (ALARM)
(SEE NOTE 6)
RD
24VAC
COM
C
OM
208
VAC
230
VAC
208
VAC
230
VAC
TR1
(SEE NOTE 1)
TR2
(SEE NOTE 1)
H2P
(COM STAT)
H3P (RX DATA)
X33A
WIRING ADAPTER
PCB
(OPTION)
REMOTE SENSOR
(OPTION)
X4A
X35A
X23A
CAPACITY SETTING
X1M
X2M
F1
T1
P2
P1
T2
F2
1
2
R
C
ECONOMIZER (OPTION)
HUMIDIFIER (OPTION)
AIR CLEANER (OPTION)
EXTERNAL CONTACT (OPTION)
OUTPUT FOR
CONTROL ON/OFF
(OPTION)
OUTPUT FOR
ECONOMIZER 2
(OPTION)
X7A
FAN
MOTOR
2
1
ECM MOTOR
BK
RD
PL1
PL2
9
3
2
6
5
4
7
8
1
BK
RD
DISCONNECT SWITCH WIRING
PL1
PL2
9
7
8
4
5
6
3
2
1
PL3
PL4
TRANSFORMER
CONNECTOR
PL3, PL4
RELAY IN
(ACC-IN)
BK
RD
GY BL
X5A
TB1
TH1
TB2
TR1
TB10
TB3
TH2
TR2
TB7
COM
F1U
F2U
SEE NOTE 7
TB5
TB4
~ ~
WH
BR
BL
GR
RD
BK
BK
RD
RD
208/230
VAC
~ ~
TRANSMISSION WIRING
REMOTE CONTROLLER WIRING
Summary of Contents for SkyAir RZQ-TA Series
Page 1: ...Service Manual Cooling Only 60 Hz Heat Pump 60 Hz RZR TA RZQ TA Series SiUS281811E...
Page 283: ...6L86 3DUW SSHQGL LULQJ LDJUDPV 2XWGRRU 8QLW QGRRU 8QLW Part 7 Appendix...
Page 284: ...LULQJ LDJUDPV 6L86 3DUW SSHQGL LULQJ LDJUDPV 2XWGRRU 8QLW 5 5 7 9 8 5 4 7 9 8 3D115455...
Page 285: ...6L86 LULQJ LDJUDPV 3DUW SSHQGL 5 5 7 9 8 5 4 7 9 8 3D115456...
Page 286: ...LULQJ LDJUDPV 6L86 3DUW SSHQGL QGRRU 8QLW 4 7 9 8 3D115647A...
Page 287: ...6L86 LULQJ LDJUDPV 3DUW SSHQGL 4 39 8 4 09 8 3D048116C...
Page 288: ...LULQJ LDJUDPV 6L86 3DUW SSHQGL 4 7 9 8 3D114844B...
Page 289: ...6L86 LULQJ LDJUDPV 3DUW SSHQGL 4 39 8 3D065984J...