7 Technical data

Installation manual

18

RZAG71~Y1

Sky Air Alpha-series

4P485927-1 – 2017.04

A2P

Printed circuit board (noise filter)

BS1~BS3 (A1P)

Push button switch

C1~C5 (A1P) (Y1
only)

Capacitor

DS1 (A1P)

Dipswitch

E1H

Bottom plate heater (option)

F*U

Fuse

HAP (A1P)

Light-emitting diode (service monitor is
green)

K1M, K3M (A1P) (Y1
only)

Magnetic contactor

K1R (A1P)

Magnetic relay (Y1S)

K2R (A1P)

Magnetic relay (Y2S)

K4R (A1P)

Magnetic relay (E1H)

K10R, K13R~K15R
(A1P)

Magnetic relay

K11M (A1P) (V1
only)

Magnetic contactor

L1R (Y1 only)

Reactor

M1C

Compressor motor

M1F~M2F

Fan motor

PFC (A1P) (V1 only)

Power factor correction

PS (A1P)

Switching power supply

Q1DI

Earth leakage circuit breaker (30 mA)

Q1E

Overload protection

R1~R8 (A1P) (Y1
only)

Resistor

R1T

Thermistor (air)

R2T

Thermistor (discharge)

R3T

Thermistor (suction)

R4T

Thermistor (heat exchanger)

R5T

Thermistor (heat exchanger middle)

R6T

Thermistor (liquid)

R7T

Thermistor (fin)

R8 (A1P) (V1 only)

Resistor

RC (A1P) (Y1 only)

Signal receiver unit

S1PH

High pressure switch

S1PL

Low pressure switch

SEG1~SEG3

7-segment display

TC1 (A1P) (V1 only)

Signal transmission circuit

TC (A1P) (Y1 only)

Signal transmission circuit

V1 (V1 only)

Varistor

V1D (A1P) (V1 only)

Diode

V1D~V2D (A1P) (Y1
only)

Diode

V*R (V1 only)

Diode module

V1R, V2R (A1P) (Y1
only)

Diode module

V3R~V5R (A1P) (Y1
only)

IGBT power module

X1M

Terminal strip

Y1E~Y3E

Electronic expansion valve

Y1S~Y2S

Solenoid valve (4‑way valve)

Z*C

Noise filter (ferrite core)

Z*F

Noise filter

L*, L*A, L*B, NA, NB,
E*, U, V, W, X*A
(A1P~A2P)

Connector

Summary of Contents for SkyAir RZAG71M7V1B

Page 1: ...Installation manual Sky Air Alpha series English Installation manual Sky Air Alpha series RZAG71M7V1B RZAG100M7V1B RZAG125M7V1B RZAG140M7V1B RZAG71M7Y1B RZAG100M7Y1B RZAG125M7Y1B RZAG140M7Y1B...

Page 2: ...1000 1000 500 HD HU HU a b 100 100 c d e eB eD A B C D E HB HD A B C 200 300 1000 A B C E 200 300 1000 1000 500 D 1000 D E 1000 1000 500 B D HD HU 300 1000 HD HU 250 1500 HU HD HU 300 1500 B D E HB H...

Page 3: ...onforme altera o em 10 11 12 13 14 15 16 17 Direktiver med senere ndringer Direktiv med f retagna ndringar Direktiver med foretatte endringer Direktiivej sellaisina kuin ne ovat muutettuina v platn m...

Page 4: ...PS vastaava kyll stysl mp tila M C Kylm aine N Varmuuspainelaitteen asetus P bar Valmistusnumero ja valmistusvuosi katso mallin nimikilpi Maxim ln p pustn tlak PS K bar Minim ln maxim ln p pustn teplo...

Page 5: ...tion 13 4 6 2 To check the insulation resistance of the compressor 14 5 Commissioning 14 5 1 Checklist before commissioning 14 5 2 To perform a test run 14 5 3 Error codes when performing a test run 1...

Page 6: ...150 6 2 0 350 3 4 5 3 5 5 4 M12 a a Make sure not to cover the drain holes of the bottom plate of the unit INFORMATION The recommended height of the upper protruding part of the bolts is 20 mm 20 NOT...

Page 7: ...cover a with screw b Remove the piping intake plate c with screw d c a b d 2 Choose a piping route a b c or d a b c d 3 If you have chosen the downwards piping route Drill a 4 and remove the knockout...

Page 8: ...t least 200 kPa 2 bar It is recommended to pressurize to 3000 kPa 30 bar in order to detect small leaks 2 Check for leaks by applying the bubble test solution to all connections 3 Discharge all nitrog...

Page 9: ...ng or recharging activate field setting vacuum mode After finishing vacuum drying or recharging deactivate field setting vacuum mode WARNING Some sections of the refrigerant circuit may be isolated fr...

Page 10: ...e of twin triple and double twin 1 Determine G1 and G2 G1 m Total length of x liquid piping x 9 5 mm standard x 12 7 mm size up G2 m Total length of 6 4 mm liquid piping 2 Determine R1 and R2 If Then...

Page 11: ...e 2 28 3 When 2 28 is reached press the BS3 button once 4 Change the setting to 1 by pressing the BS2 button once 5 Push the BS3 button once 6 When the display is not blinking anymore press the BS3 bu...

Page 12: ...per phase RZAG71 140M7Y1B Equipment complying with EN IEC 61000 3 2 European International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low vo...

Page 13: ...Routing through the frame Choose one of the 3 possibilities a b a b a b 2 3 1 a Power supply cable b Interconnection cable Connecting to the frame When cables are routed from the unit a protection sl...

Page 14: ...arthed and the earth terminals are tightened The fuses or locally installed protection devices are installed according to this document and have not been bypassed The power supply voltage matches the...

Page 15: ...wiring error between power supply and outdoor unit between outdoor unit and indoor units between indoor unit and user interface The fuse on the outdoor unit PCB has blown out E3 E4 or L8 The stop valv...

Page 16: ...les walls baffle plates E Obstacle roof a b c d e Minimum service space between the unit and obstacles A B C D and E eB Maximum distance between the unit and the edge of obstacle E in the direction of...

Page 17: ...or See note See note Outdoor Outdoor Indoor Indoor Upper Upper Lower Lower Fan Fan ON ON OFF OFF 2 Layout English Translation Layout Layout Front Front Back Back Position of compressor terminal Positi...

Page 18: ...arth leakage circuit breaker 30 mA Q1E Overload protection R1 R8 A1P Y1 only Resistor R1T Thermistor air R2T Thermistor discharge R3T Thermistor suction R4T Thermistor heat exchanger R5T Thermistor he...

Page 19: ......

Page 20: ...4P485927 1 2017 04 Copyright 2017 Daikin 4P485927 1 0000000X...

Reviews: