background image

Table of contents

Installation manual

5

RZAG71~Y1
Sky Air Alpha-series
4P573382-1 – 2019.04

Table of contents

1 About the documentation

5

1.1

About this document..................................................................

5

2 About the box

5

2.1

Outdoor unit...............................................................................

5

2.1.1

To remove the accessories from the outdoor unit.......

5

3 Preparation

6

3.1

Preparing the installation site ....................................................

6

3.1.1

Installation site requirements of the outdoor unit ........

6

4 Installation

6

4.1

Mounting the outdoor unit..........................................................

6

4.1.1

To provide the installation structure ............................

6

4.1.2

To install the outdoor unit............................................

6

4.1.3

To provide drainage ....................................................

6

4.1.4

To prevent the outdoor unit from falling over ..............

7

4.2

Connecting the refrigerant piping ..............................................

7

4.2.1

To connect the refrigerant piping to the outdoor unit ..

7

4.3

Checking the refrigerant piping .................................................

8

4.3.1

Checking refrigerant piping: Setup..............................

8

4.3.2

To check for leaks.......................................................

8

4.3.3

To perform vacuum drying ..........................................

9

4.4

Charging refrigerant ..................................................................

9

4.4.1

About charging refrigerant ..........................................

9

4.4.2

About the refrigerant ................................................... 10

4.4.3

Precautions when charging refrigerant ....................... 10

4.4.4

Definitions: L1~L7, H1, H2 .......................................... 10

4.4.5

Charging additional refrigerant.................................... 10

4.4.6

Completely recharging refrigerant............................... 11

4.4.7

To fix the fluorinated greenhouse gases label ............ 12

4.5

Connecting the electrical wiring.................................................

13

4.5.1

About electrical compliance ........................................ 13

4.5.2

Guidelines when connecting the electrical wiring ....... 13

4.5.3

Specifications of standard wiring components............ 13

4.5.4

To connect the electrical wiring on the outdoor unit.... 13

4.6

Finishing the outdoor unit installation ........................................

15

4.6.1

To finish the outdoor unit installation .......................... 15

4.6.2

To check the insulation resistance of the compressor

15

5 Commissioning

15

5.1

Checklist before commissioning ................................................

15

5.2

To perform a test run .................................................................

15

5.3

Error codes when performing a test run ....................................

16

6 Disposal

16

7 Technical data

17

7.1

Service space: Outdoor unit ......................................................

17

7.2

Piping diagram: Outdoor unit.....................................................

18

7.3

Wiring diagram: Outdoor unit ....................................................

18

1

About the documentation

1.1

About this document

Target audience

Authorised installers

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry  and  on  farms,  or  for
commercial use by lay persons.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you MUST read before installing

▪ Format: Paper (in the box of the outdoor unit)

Outdoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the outdoor unit)

Installer reference guide:

▪ Preparation of the installation, reference data,…

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

Business Portal (authentication required).

2

About the box

2.1

Outdoor unit

2.1.1

To remove the accessories from the
outdoor unit

1

2

3

ENERG

IJA

Y

IA

IE

ENERG

IJA

Y

IA

IE

b

a

c

d

e

f

a

General safety precautions

b

Outdoor unit installation manual

c

Cable tie

d

Fluorinated greenhouse gases label

e

Energy label

f

Addendum (LOT21)

Summary of Contents for Sky Air Alpha RZAG71N7V1B

Page 1: ...Installation manual Sky Air Alpha series English Installation manual Sky Air Alpha series RZAG71N7V1B RZAG100N7V1B RZAG125N7V1B RZAG140N7V1B RZAG71N7Y1B RZAG100N7Y1B RZAG125N7Y1B RZAG140N7Y1B...

Page 2: ...HD HU 200 1000 1000 500 HD HU A B C 200 1 300 1000 A B C E 200 1 300 1000 1000 500 D 1000 D E 1000 1000 500 B D HD HU 300 1000 250 1500 300 1500 B D E HB HU 300 1000 1000 500 HU HB HU 300 1250 1000 50...

Page 3: ...onforme altera o em 10 11 12 13 14 15 16 17 Direktiver med senere ndringer Direktiv med f retagna ndringar Direktiver med foretatte endringer Direktiivej sellaisina kuin ne ovat muutettuina v platn m...

Page 4: ...taava kyll stysl mp tila M C Kylm aine N Varmuuspainelaitteen asetus P bar Valmistusnumero ja valmistusvuosi katso mallin nimikilpi Maxim ln p pustn tlak PS K bar Minim ln maxim ln p pustn teplota TS...

Page 5: ...ressor 15 5 Commissioning 15 5 1 Checklist before commissioning 15 5 2 To perform a test run 15 5 3 Error codes when performing a test run 16 6 Disposal 16 7 Technical data 17 7 1 Service space Outdoo...

Page 6: ...s of anchor bolts nuts and washers field supply as follows mm 150 7 5 8 485 4 8 0 4 9 0 4 M12 a a Make sure not to cover the drain holes of the bottom plate of the unit INFORMATION The recommended hei...

Page 7: ...ggest to install the optional bottom plate heater EKBPH140N7 when the unit is installed in cold climates 4 1 4 To prevent the outdoor unit from falling over In case the unit is installed in places whe...

Page 8: ...see above with sealing material to prevent condensed water on the stop valves from moving to the indoor unit NOTICE Any exposed piping might cause condensation 6 Reattach the service cover and the pi...

Page 9: ...tal liquid piping length is more than specified see later Completely recharging refrigerant Example When relocating the system After a leak Charging additional refrigerant Before charging additional r...

Page 10: ...er a heater or a cooker this may result in fire or the formation of a harmful gas Turn off any combustible heating devices ventilate the room and contact the dealer where you purchased the unit Do NOT...

Page 11: ...5 mm RZAG100 Case Twin standard liquid pipe size 1 G1 Total 9 5 G1 45 m G2 Total 6 4 G2 7 5 12 m 2 Case G1 40 m R1 Length G1 40 m 5 m R1 0 35 kg R2 Length G2 12 m R2 0 4 kg 3 R R R1 R2 0 35 0 4 0 75...

Page 12: ...deactivate vacuum mode 12 Press the BS1 button to leave the setting mode Make sure to reattach the electronic component box cover and to install the front cover after the job is finished NOTICE Make s...

Page 13: ...3 12 European International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low voltage systems with input current 16 A and 75 A per phase 4 5 2...

Page 14: ...iring to the frame at the knockout hole Routing through the frame Choose one of the 3 possibilities a a a 2 3 1 a Power supply cable Note Route the interconnection cable together with the refrigerant...

Page 15: ...e is used The indoor unit decoration panel with infrared receiver is installed The outdoor unit is properly mounted The following field wiring has been carried out according to this document and the a...

Page 16: ...ror codes when performing a test run If the installation of the outdoor unit has NOT been done correctly the following error codes may be displayed on the user interface Error code Possible cause Noth...

Page 17: ...stacle roof a b c d e Minimum service space between the unit and obstacles A B C D and E eB Maximum distance between the unit and the edge of obstacle E in the direction of obstacle B eD Maximum dista...

Page 18: ...ON OFF OFF 2 Layout English Translation Layout Layout Front Front Back Back Position of compressor terminal Position of compressor terminal 3 Notes English Translation Notes Notes Connection X1M Indoo...

Page 19: ...erload protection R1 R8 A1P Y1 only Resistor R1T Thermistor air R2T Thermistor discharge R3T Thermistor suction R4T Thermistor heat exchanger R5T Thermistor heat exchanger middle R6T Thermistor liquid...

Page 20: ...4P573382 1 2019 04 Copyright 2019 Daikin 4P573382 1 0000000Q...

Reviews: