3 About the system

Operation manual

4

35M5V1B

Daikin room air conditioners

3P520336-13M – 2021.03

WARNING

Be careful with ladders when working
in high places.

WARNING

Improper detergents or cleaning
procedure may cause damage on
plastic components or water leakage.
Splashed detergent on electric
components, such as motors, may
cause failure, smoke or ignition.

DANGER: RISK OF
ELECTROCUTION

Before cleaning, be sure to stop the
operation, turn the breaker off or pull
out the supply cord. Otherwise, an
electric shock and injury may result.

WARNING

Stop operation and shut off the
power if anything unusual occurs
(burning smells etc.).

Leaving the unit running under such
circumstances may cause breakage,
electric shock or fire. Contact your
dealer.

3

About the system

WARNING: MILDLY FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

NOTICE

Do  NOT  use  the  system  for  other  purposes.  In  order  to
avoid  any  quality  deterioration,  do  NOT  use  the  unit  for
cooling  precision  instruments,  food,  plants,  animals,  or
works of art.

3.1

Indoor unit

CAUTION

Do  NOT  insert  fingers,  rods  or  other  objects  into  the  air
inlet or outlet. When the fan is rotating at high speed, it will
cause injury.

INFORMATION

The sound pressure level is less than 70 dBA.

WARNING

▪ Do  NOT  modify,  disassemble,  remove,  reinstall  or

repair  the  unit  yourself  as  incorrect  dismantling  or
installation may cause an electric shock or fire. Contact
your dealer.

▪ In case of accidental refrigerant leaks, make sure there

are  no  naked  flames.  The  refrigerant  itself  is  entirely
safe,  non-toxic  and  mildly  flammable,  but  it  will
generate  toxic  gas  when  it  accidentally  leaks  into  a
room  where  combustible  air  from  fan  heaters,  gas
cookers,  etc.  is  present.  Always  have  qualified  service
personnel  confirm  that  the  point  of  leakage  has  been
repaired or corrected before resuming operation.

INFORMATION

The  following  figures  are  just  examples  and  may  NOT
completely match your system layout.

3.1.1

Indoor unit display

ON/OFF

a

b

c

d

a

Signal receiver

b

Operation lamp

c

Timer lamp

d

ON/OFF button

ON/OFF button

If the user interface is missing, you can use the ON/OFF button on
the  indoor  unit  to  start/stop  operation.  When  operation  is  started
using this button, the following settings are used:

▪ Operation mode = Automatic

▪ Temperature setting = 25°C

▪ Airflow rate = Automatic

3.2

About the user interface

Direct  sunlight.

  Do  NOT  expose  the  user  interface  to  direct

sunlight.

Dust.

  Dust  on  the  signal  transmitter  or  receiver  will  reduce

sensitivity. Wipe off dust with a soft cloth.

Fluorescent  lights.

  Signal  communication  might  be  disabled  if

fluorescent  lamps  are  in  the  room.  In  that  case,  contact  your
installer.

Other  appliances.

  If  the  user  interface  signals  operate  other

appliances, move the other appliances, or contact your installer.

Curtains.

 Make sure that the signal between the unit and the user

interface is NOT blocked by curtains or other objects.

NOTICE

▪ Do NOT drop the user interface.

▪ Do NOT let the user interface get wet.

Summary of Contents for Siesta ATXTP25M5V1B

Page 1: ...Operation manual Daikin room air conditioners English Operation manual Daikin room air conditioners ATXTP25M5V1B ATXTP35M5V1B...

Page 2: ...um apatite deodorising filter and the silver particle filter Ag ion filter 10 7 8 To close the front panel 10 7 9 To take following items into account before a long idle period 10 7 9 1 Winter season...

Page 3: ...lammable but normally does NOT leak If the refrigerant leaks in the room and comes in contact with fire from a burner a heater or a cooker this may result in fire or the formation of a harmful gas Tur...

Page 4: ...ctric shock or fire Contact your dealer In case of accidental refrigerant leaks make sure there are no naked flames The refrigerant itself is entirely safe non toxic and mildly flammable but it will g...

Page 5: ...nterface holder c b a 2 a User interface b Screws field supply c User interface holder 1 Choose a place where the signals reach the unit 2 Attach the holder with screws to the wall or a similar locati...

Page 6: ...omatic operation Drying or fan only operation 18 32 C 10 30 C 18 30 C 3 Press to stop operation Result The operation lamp goes off 5 3 Airflow rate INFORMATION When using drying operation mode you CAN...

Page 7: ...to the position from before the Comfort airflow mode disappears from the LCD 5 6 Powerful operation This operation quickly maximizes the cooling heating effect in any operation mode You can get the m...

Page 8: ...timer operation 4 8 and 5 8 2 To start stop ON timer operation 48 Result and are displayed on the LCD Example 2 If is set when the unit is operating Result Operation stops in 1 hour and then starts 7...

Page 9: ...ontaining water on the unit CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury CAUTION Do NOT touch the heat exchanger fins These fi...

Page 10: ...After washing shake off remaining water and dry the filter in the shade Do NOT wring out the filter when removing water 7 7 To replace the titanium apatite deodorising filter and the silver particle f...

Page 11: ...OFF switch does NOT properly work Turn OFF the main power switch If water leaks from the unit Stop the operation The operation switch does NOT work well Turn OFF the power supply The operation lamp fl...

Page 12: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P520336 13M 2021 03 Copyright 2...

Reviews: