7 Maintenance and service

Operation manual

9

35M5V1B
Daikin room air conditioners
3P520336-13M – 2021.03

WARNING

The  refrigerant  inside  the  unit  is  mildly  flammable,  but
normally  does  NOT  leak.  If  the  refrigerant  leaks  in  the
room  and  comes  in  contact  with  fire  from  a  burner,  a
heater, or a cooker, this may result in fire, or the formation
of a harmful gas.

Turn  off  any  combustible  heating  devices,  ventilate  the
room,  and  contact  the  dealer  where  you  purchased  the
unit.

Do  NOT  use  the  unit  until  a  service  person  confirms  that
the  part  from  which  the  refrigerant  leaked  has  been
repaired.

WARNING

▪ Do NOT pierce or burn refrigerant cycle parts.

▪ Do NOT use cleaning materials or means to accelerate

the  defrosting  process  other  than  those  recommended
by the manufacturer.

▪ Be  aware  that  the  refrigerant  inside  the  system  is

odourless.

WARNING

The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating  ignition  sources  (e.g.  open  flames,  an  operating
gas  appliance,  or  an  operating  electric  heater).  The  room
size shall be as specified in the General safety precaution.

NOTICE

Maintenance  MUST  be  done  by  an  authorized  installer  or
service agent.

We  recommend  performing  maintenance  at  least  once  a
year. However, applicable legislation might require shorter
maintenance intervals.

DANGER: RISK OF ELECTROCUTION

To  clean  the  air  conditioner  or  air  filter,  be  sure  to  stop
operation  and  turn  all  power  supplies  off.  Otherwise,  an
electric shock and injury may result.

WARNING

To prevent electrical shocks or fire:

▪ Do NOT rinse the unit.

▪ Do NOT operate the unit with wet hands.

▪ Do NOT place any objects containing water on the unit.

CAUTION

After  a  long  use,  check  the  unit  stand  and  fitting  for
damage. If damaged, the unit may fall and result in injury.

CAUTION

Do  NOT  touch  the  heat  exchanger  fins.  These  fins  are
sharp and could result in cutting injuries.

WARNING

Be careful with ladders when working in high places.

Following symbols may occur on the indoor unit:

Symbol

Explanation

Measure the voltage at the terminals of main circuit
capacitors or electrical components before servicing.

7.2

To clean the indoor unit and user
interface

WARNING

Improper  detergents  or  cleaning  procedure  may  cause
damage  on  plastic  components  or  water  leakage.
Splashed  detergent  on  electric  components,  such  as
motors, may cause failure, smoke or ignition.

NOTICE

▪ Do  NOT  use  gasoline,  benzene,  thinner,  polishing

powder  or  liquid  insecticide. 

Possible  consequence:

Discoloration and deformation.

▪ Do  NOT  use  water  or  air  of  40°C  or  higher. 

Possible

consequence: 

Discoloration and deformation.

▪ Do NOT use polishing compounds.

▪ Do 

NOT 

use 

scrubbing 

brush. 

Possible

consequence: 

The surface finishing peels off.

▪ As an end user, you may NEVER clean inside parts of

the unit by yourself; this work must be performed by a
qualified service person. Contact your dealer.

DANGER: RISK OF ELECTROCUTION

Before  cleaning,  be  sure  to  stop  the  operation,  turn  the
breaker  off  or  pull  out  the  supply  cord.  Otherwise,  an
electric shock and injury may result.

1

Clean  with  a  soft  cloth.  If  it  is  difficult  to  remove  stains,  use
water or a neutral detergent.

7.3

To clean the front panel

1

Clean the front panel with a soft cloth. If it is difficult to remove
stains, use water or a neutral detergent.

7.4

To open the front panel

1

Hold the front panel by the panel tabs on both sides and open
it.

7.5

To clean the air filters

1

Push the tab at the centre of each air filter, then pull it down.

2

Pull out the air filters.

Summary of Contents for Siesta ATXTP25M5V1B

Page 1: ...Operation manual Daikin room air conditioners English Operation manual Daikin room air conditioners ATXTP25M5V1B ATXTP35M5V1B...

Page 2: ...um apatite deodorising filter and the silver particle filter Ag ion filter 10 7 8 To close the front panel 10 7 9 To take following items into account before a long idle period 10 7 9 1 Winter season...

Page 3: ...lammable but normally does NOT leak If the refrigerant leaks in the room and comes in contact with fire from a burner a heater or a cooker this may result in fire or the formation of a harmful gas Tur...

Page 4: ...ctric shock or fire Contact your dealer In case of accidental refrigerant leaks make sure there are no naked flames The refrigerant itself is entirely safe non toxic and mildly flammable but it will g...

Page 5: ...nterface holder c b a 2 a User interface b Screws field supply c User interface holder 1 Choose a place where the signals reach the unit 2 Attach the holder with screws to the wall or a similar locati...

Page 6: ...omatic operation Drying or fan only operation 18 32 C 10 30 C 18 30 C 3 Press to stop operation Result The operation lamp goes off 5 3 Airflow rate INFORMATION When using drying operation mode you CAN...

Page 7: ...to the position from before the Comfort airflow mode disappears from the LCD 5 6 Powerful operation This operation quickly maximizes the cooling heating effect in any operation mode You can get the m...

Page 8: ...timer operation 4 8 and 5 8 2 To start stop ON timer operation 48 Result and are displayed on the LCD Example 2 If is set when the unit is operating Result Operation stops in 1 hour and then starts 7...

Page 9: ...ontaining water on the unit CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury CAUTION Do NOT touch the heat exchanger fins These fi...

Page 10: ...After washing shake off remaining water and dry the filter in the shade Do NOT wring out the filter when removing water 7 7 To replace the titanium apatite deodorising filter and the silver particle f...

Page 11: ...OFF switch does NOT properly work Turn OFF the main power switch If water leaks from the unit Stop the operation The operation switch does NOT work well Turn OFF the power supply The operation lamp fl...

Page 12: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P520336 13M 2021 03 Copyright 2...

Reviews: