![Daikin Siesta ATXM20N2V1B User Reference Manual Download Page 17](http://html1.mh-extra.com/html/daikin/siesta-atxm20n2v1b/siesta-atxm20n2v1b_user-reference-manual_2460060017.webp)
5
|
Operation
User reference guide
17
ATXM20~50N2V1B
Daikin room air conditioner
4P518786-2F – 2020.05
5 Operation
5.1 Operation range
Use the system in the following temperature and humidity ranges for safe and
effective operation.
In combination with outdoor units: 2AMXM and 3AMXM
Cooling and drying
(a)
Heating
(a)
Outdoor temperature
–10~46°C DB
–15~24°C DB
–15~18°C WB
Indoor temperature
18~37°C DB
14~28°C WB
10~30°C DB
Indoor humidity
≤80%
(b)
—
In combination with other outdoor units
Cooling and drying
(a)
Heating
(a)
Outdoor temperature
–10~50°C DB
–20~24°C DB
–21~18°C WB
Indoor temperature
18~37°C DB
14~28°C WB
10~30°C DB
Indoor humidity
≤80%
(b)
—
If operated outside the operation range:
(a) A safety device might stop the operation of the system.
(b) Condensation might occur on the indoor unit and drip.
5.2 When to use which feature
You can use the following table to determine which features to use:¨
INFORMATION
Operation modes:
cooling
,
drying
and
automatic
are NOT available for the
heating
only
version of the product.
Feature
Tasks
Basic features
Summary of Contents for Siesta ATXM20N2V1B
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ...4P518786 2F 2020 05 Copyright 2018 Daikin Verantwortung f r Energie und Umwelt...