background image

5 Operation

Operation manual

11

ATXM-A
Daikin room air conditioner
3P728539-4 – 2023.06

5.9.2

12 hour countdown OFF/ON timer setting

To start/stop countdown OFF/ON timer operation

1

Press  and  hold 

  or 

  for  about  5  seconds;

when   blinks, release the button.

Result: 

For the OFF timer, 

 appears on the LCD and 

blinks,   and the day of the week disappear from the
LCD.

For the ON timer, 

 appears on the LCD and 

blinks.   and the day of the week disappear from the
LCD.

2

Press 

 or 

 to change the time setting. The time can be

set between 1~12 hours. Each pressing of the button increases
or decreases the time setting by 1 hour.

3

Press 

 or 

 to confirm the setting.

Result: 

 and/or 

 and the set time are displayed on the LCD.

The  Daikin  eye  lights  orange.  The  time  displayed  on  the  LCD  will
automatically count down by 1 hour for every hour that passes.

Example: 

 If the OFF timer is set to 3 hours, the displayed time will

change as follows: 3hr → 2hr → 1hr → blank (OFF)

4

To  change  the  setting  back  to  24  hour  OFF/ON  timer,  repeat
step  1  when  on  the  home  screen  when 

  and/or 

  are

NOT blinking.

5

To cancel the timer setting, press 

.

To combine the timer display modes

Different  display  modes  (24  hour  and  12  hour  countdown  OFF/ON
timer) can be used for the OFF timer and ON timer simultaneously.

1

For  setting,  see 

"To  start/stop  OFF  timer  operation"

  [

4

  10], 

"To

start/stop  ON  timer  operation"

  [

4

  10]  and 

"To  start/stop

countdown OFF/ON timer operation"

 [

4

 11].

Example:

Display

Current time

Set while…

Operation

22:00

the unit is
operating.

▪ Stops  at  1:00

(3  hours  after
present time)

▪ Starts 

at

6:00. (8 hours
after  present
time)

Note: 

 If the timer setting is active, the current time is NOT displayed

on the LCD.

5.10

Weekly timer operation

INFORMATION

The  following  setting  procedure  is  for  the  wireless  remote
control  only.  However,  we  recommend  to  perform  the
weekly  timer  setting  using  the  ONECTA  app.  Refer  to

"5.11  Wireless  LAN  connection"

  [

4

  13]  for  more

information.

With this operation, you can save up to 4 timer settings for each day
of the week.

Example: 

Create  a  different  setting  from  Monday  to  Friday  and  a

different setting for weekends.

Day of the week

Setting example

Monday

▪ Make up to 4 settings.

6:00

8:30

17:30

25°C

27°C

25°C

22:00

1

2

3

4

ON

OFF

ON

OFF

Tuesday~Friday

▪ Use the copy mode if the

settings are the same as
for Monday.

6:00

8:30

17:30

25°C

27°C

25°C

22:00

1

2

3

4

ON

OFF

ON

OFF

Saturday

▪ No timer setting

Sunday

▪ Make up to 4 settings.

8:00 10:00

19:00 21:00

27°C

27°C

25°C

ON

OFF

OFF

ON

1

2

3

4

ON-ON-ON-ON  setting.

  Enables  scheduling  the  operation  mode

and set temperature.

OFF-OFF-OFF-OFF setting.

 Only the turn off time can be set for

each day.

Note: 

 Be sure to aim the wireless remote control at the indoor unit

and  check  for  a  receiving  tone  when  setting  the  Weekly  timer
operation.

INFORMATION

The  clock  MUST  be  set  correctly  before  using  any  timer
functions. Refer to 

"4.3 To set the clock"

 [

4

 6].

INFORMATION

▪ Weekly timer and OFF/ON timer operation CANNOT be

used  at  the  same  time.  The  OFF/ON  timer  operation
takes priority. Weekly timer will be in standby, 
disappears  from  the  LCD.  When  the  OFF/ON  timer  is
completed, the Weekly timer becomes active.

▪ The  day  of  the  week,  OFF/ON  timer  mode,  time  and

temperature  (only  for  ON  timer)  can  be  set  with  the
Weekly timer. Other settings are based on previous ON
timer setting.

5.10.1

To set Weekly timer operation

1

Press 

.

Result: 

The day of the week and the reservation number of the

current day are displayed.

2

Press 

  or 

  to  select  the  day  of  the  week  and  the

reservation number.

3

Press 

.

Result: 

The day of the week is set. 

 and 

 blink.

4

Press 

 or 

 to select the mode.

Result: 

The setting will change as follows:

Display

Feature

ON timer

OFF timer

Summary of Contents for Siesta ATXM20A2V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner ATXM20A2V1B ATXM25A2V1B ATXM35A2V1B ATXM50A2V1B ATXM20A5V1B ATXM25A5V1B ATXM35A5V1B ATXM50A5V1B...

Page 2: ...11 1 Precautions when using the wireless LAN 13 5 11 2 To install the ONECTA app 13 5 11 3 To set the wireless connection 13 6 Energy saving and optimum operation 15 7 Maintenance and service 15 7 1...

Page 3: ...rmation contact your installer or local authority Batteries are marked with the following symbol This means that the batteries may NOT be mixed with unsorted household waste If a chemical symbol is pr...

Page 4: ...the unit until a service person confirms that the part from which the refrigerant leaked has been repaired WARNING Do NOT pierce or burn refrigerant cycle parts Do NOT use cleaning materials or means...

Page 5: ...are no naked flames The refrigerant itself is entirely safe non toxic and mildly flammable but it will generate toxic gas when it accidentally leaks into a room where combustible air from fan heaters...

Page 6: ...w and Intelligent eye operation button h Select button i Clock and indoor unit display brightness button j OFF ON timer operation buttons k Weekly timer operation buttons l Flash Streamer air cleaning...

Page 7: ...it runs outside its operation range 5 2 Operation mode and temperature setpoint When Adjust the system operation mode and set the temperature when you want to Heat up or cool down a room Blow air in a...

Page 8: ...aries according to the operation mode The flap will stop at the upper position when the airflow rate is changed to low during the up and down swing setting 5 4 1 To adjust vertical airflow direction 1...

Page 9: ...r that operation returns to the previously set mode 2 Press to stop Result disappears from the LCD Note Powerful operation can be set only when the unit is running If you press or if you change operat...

Page 10: ...ions Refer to 4 3 To set the clock 46 5 9 1 24 hour clock OFF ON timer setting To start stop OFF timer operation 1 Press to start Result is displayed on the LCD and blinks and the day of the week disa...

Page 11: ...re is for the wireless remote control only However we recommend to perform the weekly timer setting using the ONECTA app Refer to 5 11 Wireless LAN connection 4 13 for more information With this opera...

Page 12: ...complete reservation of the selected day of the week will be copied 1 Press 2 Press or to select the day of the week to be copied 3 Press Result The reservation of the selected day of the week will b...

Page 13: ...uipment E g persons using cardiac pacemakers or defibrillators This product may cause electromagnetic interference Auto control equipment E g automatic doors or fire alarm equipment This product may c...

Page 14: ...ber 414 5 Press to exit the menu Result The display will return to the default screen To connect using SSID and KEY number 1 On home screen menu hold for at least 5 seconds while the unit is not opera...

Page 15: ...ty in CO2 equivalent tonnes GWP value of the refrigerant total refrigerant charge in kg 1000 Contact your installer for more information NOTICE Maintenance MUST be done by an authorised installer or s...

Page 16: ...se a scrubbing brush Possible consequence The surface finishing peels off As an end user you may NEVER clean inside parts of the unit by yourself this work must be performed by a qualified service per...

Page 17: ...anel Align the shafts with the slots and push them all the way in 2 Close the front panel slowly press at both sides and at the centre 8 Troubleshooting If one of the following malfunctions occur take...

Page 18: ...2023 06 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST be...

Page 19: ......

Page 20: ...TANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P728539 4 2023 06 Copyright 20...

Reviews: