![background image](http://html1.mh-extra.com/html/daikin/sibe041010/sibe041010_service-manual_2460045137.webp)
SiBE041010
Outdoor Unit
Removal Procedure
127
3
Disconnect the
connector for electronic
expansion valve coil
[S20].
4
Detach the clamp of the
lead wire for the
electronic expansion
valve coil.
5
Disconnect the relay
connector for the
compressor motor.
Pay attention so as not to
lose the fixture.
When reassembling, do not
insert the thermistor up to
the dent of fixture.
6
Release the discharge
pipe thermistor.
Step
Procedure
Points
[S20]
(R7390)
Clamp
(R7391)
(R7392)
Dent
Fixture
Discharge pipe thermistor
(R7393)