![background image](http://html1.mh-extra.com/html/daikin/sibe041010/sibe041010_service-manual_2460045118.webp)
Indoor Unit
SiBE041010
108
Removal Procedure
1.5
Removal of Electrical Box / Vertical Blades
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. Disconnect the connecting
wires.
Preparation
Remove the front grille
according to the “Removal
of Front Grille”.
1
The figure shows the
connections of wire
harnesses.
2
Remove the screw of
the wire retaining plate.
3
Loosen the screws of
the terminal board and
disconnect the
connecting wires.
(1) Black - Power Supply
(2) White - Power Supply
(3) Red - Signal
4
Pull out the indoor heat
exchanger thermistor.
Take care not to lose the clip
of thermistor.
Terminal board
Electrical box
Wire retaining plate
Indoor heat exchanger thermistor
(R11954)
(R8001)
Terminal board
(R11955)
Connecting
wires
(R8003)
Indoor heat exchanger thermistor
Clip
(R11268)