![background image](http://html1.mh-extra.com/html/daikin/sibe041010/sibe041010_service-manual_2460045114.webp)
Indoor Unit
SiBE041010
104
Removal Procedure
5
Remove the horizontal
blade.
2. Remove the fan guard.
1
Unfasten the hooks at
the lower part of the fan
guard with a flat
screwdriver.
2
Unfasten the hooks at
the upper 2 positions.
3
Remove the fan guard.
Remove the other fan guard
in the same way.
Step
Procedure
Points
(R7996)
(R11959)
Fan guard
(R7998)
(R7999)