• Split - Sky Air • RZQSG-L(8)Y1
17
• Outdoor Unit • RZQSG-L(8)Y1
6
Capacity tables
6 - 1 Cooling/Heating Capacity Tables
RZQSG140L9V1
RZQSG140LY1
Cooling
Heating
Symbols
AFR: Air
flow
rate
[m³/min]
BF: Bypass
factor
EWB: Entering
wet
Ͳ
bulb
temperature
(°C
WB)
EDB: Entering
dry
Ͳ
bulb
temperature
(°C
DB)
TC: Maximum
total
cooling/heating
capacity
[kW]
SHC: Sensible
heat
capacity
[kW]
CPI: Coefficient
of
the
power
input
PI: Power
input
[kW]
compressor
+
indoor
and
outdoor
fan
motors
Cooling
Heating
Notes
1. The
ratings
shown
are
net
capacities
which
include
a
deduction
for
indoor
fan
motor
heat.
2.
= Maximum
at
standard
conditions
= Rated
capacity
and
rated
coefficient
of
the
power
input
The
maximum
capacity
is
not
guaranteed
except
at
standard
conditions.
3. SHC
is
based
on
indoor
units
EWB
&
EDB.
SHC
for
other
dry
Ͳ
bulb
temperatures
=
SHC
+
SHC*
SHC*
= SHC
correction
for
other
dry
Ͳ
bulb
temperatures
= 0.02
x
AFR
(m³/min)
x
(1
Ͳ
BF)
x
(DB*
Ͳ
EDB)
4. The
capacities
are
based
on
the
following
conditions:
Outdoor
air:
85%
RH
However,
the
outdoor
ambient
condition
of
the
rated
capacity
during
heating
operation
is
7°C
DB
/
6°C
WB.
Corresponding
refrigerant
piping
length:
5.0
m
Level
difference:
0m
5. CPI
is
a
percentage
value
compared
to
the
rated
value
which
is
1.00.
6. The
error
rate
for
this
value
is
less
than
5%
and
depends
on
the
indoor
unit
type.
7. The
heating
performance
takes
into
account
the
drop
that
occurs
during
defrost
operation.
8. The
air
flow
rate
and
bypass
factor
are
mentioned
in
the
table.
9. The
rated
power
input
for
each
model
is
mentioned
in
the
table
below.
Pair
Pair
FCQHG140F
FCQG140F
FBQ140C
FHQG140C
FVQ140C
FHQ140CA
FBQ140D
FCQHG140F
FCQG140F
FBQ140C
FHQG140C
FVQ140C
FHQ140CA
FBQ140D
Cooling
4,17
4,45
4,44
4,45
4,45
4,45
4,38
Heating
4,29
4,54
4,54
4,54
4,54
4,54
4,56
Twin
Twin
FCQHG71F
X
2 FCQG71F
X
2
FBQ71C
X
2
FHQG71C
X
2
FAQ71C
X
2
FHQ71CA
X
2
FBQ71D
X
2
FCQHG71F
X
2 FCQG71F
X
2
FBQ71C
X
2
FHQG71C
X
2
FAQ71C
X
2
FHQ71CA
X
2
FBQ71D
X
2
Cooling
4,11
4,39
4,17
4,01
4,23
4,01
4,17
Heating
4,23
4,48
4,94
4,71
4,92
4,71
4,94
Triple
Triple
FCQG50F
X
3
FBQ50C
X
3
FHQ50CA
X
3
FFQ50C
X
3
FDXS50F9
X
3
FBQ50D
X
3
FNQ50A
X
3
FCQG50F
X
3
FBQ50C
X
3
FHQ50CA
X
3
FFQ50C
X
3
FDXS50F9
X
3
FBQ50D
X
3
FNQ50A
X
3
Cooling
4,40
4,17
4,67
4,43
4,68
4,17
4,68
Heating
4,48
4,94
5,67
4,39
4,61
4,94
4,61
Double
twin
Double
twin
FCQG35F
X
4
FBQ35C
X
4
FHQ35CA
X
4
FFQ35C
X
4
FDXS35F
X
4
FBQ35D
X
4
FNQ35A
X
4
FCQG35F
X
4
FBQ35C
X
4
FHQ35CA
X
4
FFQ35C
X
4
FDXS35F
X
4
FBQ35D
X
4
FNQ35A
X
4
Cooling
4,56
4,17
4,65
4,11
5,80
4,17
5,80
Heating
4,54
4,94
5,57
4,05
6,09
4,94
6,09
15
x
4
(0.08
x
4)
8.7
x
4
(0.17
x
4)
AFR
(BF)
12.5
x
4
(0.4
x
4)
16
x4
(0.15
x
4)
14
x
4
(0.20
x
4)
10
x
4
(0.25
x
4)
8.7
x
4
(0.17
x
4)
16
x
3
(0.11
x
3)
15
x
3
(0.13
x
3)
16
x
3
(0.11
x
3)
20.5
x
2
(0.13
x
2)
18
x
2
(0.13
x
2)
AFR
(BF)
12.6
x
3
(0.22
x
3)
16
x
3
(0.16
x
3)
15
x
3
(0.18
x
3)
12
x
3
(0.16
x
3)
AFR
(BF)
21.2
x
2
(0.2
x2)
21.5
x
2
(0.14
x
2)
18.0
x
2
(0.08
x
2)
20.5
x
2
(0.13
x
2)
18.0
x
2
(0.16
x
2)
30.0
(0.18)
34.0
(0.17)
34.0
(0.06)
AFR
(BF)
33.5
(0.15)
33.0
(0.23)
39:C/41:H
(0.14)
34.0
(0.17)
Co
effic
ie
nt
of
the
powe
r
input
Co
effic
ie
nt
of
the
powe
r
input
Cooling
capacity
[kW]
Heating
capacity
[kW]
Capacity
range
Rated
point
Capacity
range
Rated
point
Indoor
Indoor
Outdoor
temperature
[°C
DB]
Outdoor
temperature
[°C
WB]
3D076755E