background image

• Outdoor Units • R-410A • RZQ71-140C7V1B

1

5

• Split Sky Air • Outdoor Units

9

5

Capacity tables

5 - 1

Combination table

3TW30469-1

NOTES

1 See main specifications table about MAX cooling capacity & heating capacity.
2 Combinations are possible regardingless type of I/U. (e.g. RZQS100 can be combined with FFQ50 + FBQ50)
3 Individual indoor capacities are not given because the combinations are for simultaneous operation (=indoor units installed in same room).
4 When different indoor models are used in combination, designate the infrared remote controller that is equipped with the most functions as the main unit.

In table above are the indoor units mentioned in order of the possible function (most functions are on FCQ, less functions are on FAQ).

5 Refnet kits that are necessary to install the combinations:

Twin:

KHRQ22M20TA

Triple:

KHRQ127H

P = Pair

71

100

2 = Twin

35+35

50+50

3 = Triple

35+35+35

Model name

Hi casette

2x2 cassette

Thin cassette

Duct (medium ESP)

4way ceiling

Ceiling suspended

Outdoor unit

Wall mounted

Refrigerant

R410A

Possible indoor combination

Simultaneous operation

Outdoor models

Twin

Triple

Double twin

RZQ100C7V1B

50-50

(KHRQ22M20TA)

35-35-35

(KHRQ127H)

RZQ125C7V1B

60-60

(KHRQ22M20TA)

50-50-50

(KHRQ127H)

35-35-35-35

(3x KHRQ22M20TA)

RZQ140C7V1B

71-71

(KHRQ22M20TA)

50-50-50

(KHRQ127H)

35-35-35-35

(3x KHRQ22M20TA)

3TW29189-1

NOTES

1

Possible indoor units: FCQH71C, FCQ35-71C, FFQ35-60BV, FHQ35-71B, FBQ35-71B, FAQ71B, FUQ71B

2

Individual indoor capacities are not given because the combinations are for simultaneous operation (=indoor units installed in same room).

3

When different indoor models are used in combination, designate the infrared remote controller that is equipped with the most functions as the

main unit.

In note 1 are the indoor units mentioned in order of the possible function (most functions are on FCQ, less functions are on FAQ).

4

Between brackets are the required Refnet kits mentioned, that are necessary to install the combination.

Out

In

In

Out

In

In

In

Possible combinations and standard capacity for twin, triple and double twin application

In

In

In

Out

In

Summary of Contents for RZQ71C7V1B

Page 1: ...rgy efficiency and very low sound level An inverter driven compressor allows the capacity to be adjusted precisely to match variations in room and outside temperatures During start up the room can be...

Page 2: ...P Nominal 3 62 3 71 3 54 3 21 Energy Label Cooling A A A D Heating A A B C Annual energy consumption kWh 1 055 1385 1940 2680 Indoor Units FBQ71B8V3B FBQ100B8V3B FBQ125B8V3B FBQ140B8V3B Cooling capaci...

Page 3: ...terial Paintable galvanized steel plate Dimensions Unit Height mm 770 1170 1170 1170 Width mm 900 900 900 900 Depth mm 320 320 320 320 Packing Height mm 900 1349 1349 1349 Width mm 980 980 980 980 Dep...

Page 4: ...l Expansion valve electronic type Nr of Circuits 1 1 1 1 Refrigerant Oil Type FVC50K Daphne FVC68D Daphne FVC68D Daphne FVC68D Charged Volume l 0 75 1 0 1 0 1 0 Piping connections Liquid OD Quantity 1...

Page 5: ...Power Supply Name V1 Phase 1 1 1 1 Frequency Hz 50 50 50 50 Voltage V 220 240 Voltage range Minimum V 198 198 198 198 Maximum V 264 264 264 264 Current Recomended fuses A 20 32 32 32 Wiring connection...

Page 6: ...B 2 TOCA means the total value of each OC set 3 Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed operation range lim...

Page 7: ...ns the total value of each OC set 3 Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed operation range limits 4 Maximu...

Page 8: ...RZQ71 140C7V1B 4 Options RZQ100 125 140C Name of option Kit name RZQ100C7V1B RZQ125C7V1B RZQ140C7V1B Central drain plug KKPJ5F180 Refrigerant branch piping Twin KHRQ22M20TA Triple KHRQ127H Double twi...

Page 9: ...edium ESP 4way ceiling Ceiling suspended Outdoor unit Wall mounted Refrigerant R410A Possible indoor combination Simultaneous operation Outdoor models Twin Triple Double twin RZQ100C7V1B 50 50 KHRQ22M...

Page 10: ...4way ceiling EDP room specifications Ceiling suspended Outdoor unit Wall mounted Refrigerant R410A 3TW29189 2 NOTES 1 Individual indoor capacities are not given because the combinations are for simult...

Page 11: ...2 On the figure the mark j show the max at standard conditions On the figure the mark Q show rated capacity and rated coefficient of power input However the max capacity is not guaranteed except at s...

Page 12: ...rated capacity is 7 C DB 6 C WB heating Corresponding refrigerant piping length 5 0m Level difference 0m 5 Coefficient of power input is the percentage when the rated value is defined as 1 00 6 The va...

Page 13: ...ping length 5 0m Level difference 0m 5 Coefficient of power input is the percentage when the rated value is defined as 1 00 6 The value contains less than 5 error acording to indoor unit type 7 Heatin...

Page 14: ...DB 6 C WB heating Corresponding refrigerant piping length 5 0m Level difference 0m 5 Coefficient of power input is the percentage when the rated value is defined as 1 00 6 The value contains less than...

Page 15: ...nly valid for pair combination with FBQ140 2 Ratings shown are net capacities which include a deduction for indoor fan motor heat 3 On the figure the mark j show the max at standard conditions On the...

Page 16: ...door Units 16 Outdoor Units R 410A RZQ71 140C7V1B 5 Capacity tables 5 2 Cooling capacity tables 3TW26062 1 RZQ B C Capacity Field piping length m Cooling Heating Capacity in function of field piping l...

Page 17: ...ties which include a deduction for indoor fan motor heat 2 On the figure the mark j show the max at standard conditions On the figure the mark Q show rated capacity and rated coefficient of power inpu...

Page 18: ...7 C DB 6 C WB heating Corresponding refrigerant piping length 5 0m Level difference 0m 5 Coefficient of power input is the percentage when the rated value is defined as 1 00 6 The value contains less...

Page 19: ...t of power input is the percentage when the rated value is defined as 1 00 6 The value contains less than 5 error acording to indoor unit type 7 Heating performance include the drop of frost formation...

Page 20: ...erant piping length 5 0m Level difference 0m 5 Coefficient of power input is the percentage when the rated value is defined as 1 00 6 The value contains less than 5 error acording to indoor unit type...

Page 21: ...oefficient of power input NOTES 1 This capacity table is only valid for pair combination with FBQ140 2 Ratings shown are net capacities which include a deduction for indoor fan motor heat 3 On the fig...

Page 22: ...5 Refrigerant piping intake 6 Power supply wiring intake knock out hole J34 7 Control wiring intake Knock out hole J27 8 Drain outlet RZQ C Hole for anchor bolt 4 M12 3TW26364 1 1 Gas pipe connection...

Page 23: ...Outdoor Units R 410A RZQ71 140C7V1B 1 6 Split Sky Air Outdoor Units 23 6 Dimensional drawing centre of gravity 6 2 Centre of gravity 4TW30469 3 RZQ71C7V1B 4TW29169 4 RZQ100 125 140C...

Page 24: ...ressure switch Filter Low pressure sensor 3TW29165 2 RZQ71 140C Twin Indoor unit Field piping J15 9 Field piping J9 5 Low pressure sensor Heat exchanger Filter Stop valve with service port 5 16 flare...

Page 25: ...ranch and the indoor units should have the same size as the indoor connections 3TW29165 4 RZQ100 125 140C Double twin Indoor unit Field piping J15 9 Field piping J9 5 Low pressure sensor Heat exchange...

Page 26: ...rcuit board Main A2P Printed circuit board Inverter BS1 BS4 Push button switch C1 C3 Capacitor DS1 Dip switch F1U Fuse T 6 3A 250V F6U Fuse T 3 15A 250V H1P 7P A2P Light emitting diode service monitor...

Page 27: ...ssure level A scale according to IEC 3 Reference acoustic pressure 0dB 20 Pa 4 Data is valid at nominal operation condition Measuring location discharge side 3TW29167 1 Sound pressure level dB Octave...

Page 28: ...peration condition 3 dB A A weighted sound pressure level A scale according to IEC 4 Reference acoustic pressure 0dB 20 Pa Measuring location discharge side 3TW29207 1 Sound pressure level dB Octave b...

Page 29: ...0CV1 NOTES 1 dB A A weighted sound pressure level A scale according to IEC 2 Reference acoustic intensity 0dB 10E 6 W m2 3 Measured according to ISO 3744 3TW29197 3 Sound power level dB Octave band ce...

Page 30: ...per row RZQ71 140C A Non stacked installation 2 Obstacles exist in front of the air inlet B Stacked installation Legend C Multiple row installation Relation of dimensions of H A and L are shown in the...

Page 31: ...g To reduce the freeze up operation indoor de icing frequency it is recommended to install the outdoor unit in a location not exposed to wind 3TW29163 2 RZQ71 140C7V1B EDP ROOM Outdoor temp CDB Operat...

Reviews: