background image

9

STOPPING THE SYSTEM

3

Press the ON/OFF button of the remote 
controller once again. The operation lamp 
goes off and the system stops operating.

NOTICE

Do not turn off power immediately after the 
unit stops, but wait for at least 5 minutes.

INFORMATION

For another remote controller, refer to the 
operation manual of the remote controller.

7. 

Energy saving and optimum 

operation

Observe the following precautions to ensure the 
system operates properly.

•  Adjust the air outlet properly and avoid direct air 

flow to room inhabitants.

•  Adjust the room temperature properly for a 

comfortable environment. Avoid excessive 
heating or cooling.

•  Prevent direct sunlight from entering a room 

during cooling operation by using curtains or 
blinds.

•  Ventilate often.

 

Extended use requires special attention to 
ventilation. 

•  Keep doors and windows closed. If the doors 

and windows remain open, air will flow out of 
your room causing a decrease in the cooling or 
heating effect.

•  Be careful not to cool or heat too much. To save 

energy, keep the temperature setting at a 
moderate level.

•  Never place objects near the air inlet or the air 

outlet of the unit. 

 

It may cause deterioration in the effect or stop 
the operation.

•  Turn off the main power supply switch to the unit 

when the unit is not used for longer periods of 
time. If the switch is on, it consumes electricity. 
Before restarting the unit, turn on the main 
power supply switch 6 hours before operation to 
ensure smooth running. (Refer to “Maintenance” 
in the indoor unit manual.)

•  When the display shows “ 

 ” (time to clean 

the air filter), ask a qualified service person to 
clean the filters. (Refer to “Maintenance” in the 
indoor unit manual.)

•  Keep the indoor unit and remote controller at 

least 1 m away from televisions, radios, stereos, 
and other similar equipment. Failing to do so 
may cause static or distorted pictures.

•  Do not place items under the indoor unit, 

 

they may be damaged by water.

•  Condensation may form if the humidity is above 

80% or if the drain outlet gets blocked.

Your system is equipped with advanced energy 
saving functionality. Depending on the priority 
emphasises can be put on energy saving or 
comfort level. Several parameters can be selected, 
resulting in the optimal balance between energy 
consumption and comfort for your particular 
application.
Several patterns are available and roughly 
explained below. Contact your installer or dealer 
for advice or to modify the parameters to the 
needs of your building.
Detailed information is given for the installer in the 
installation manual. He can help you to realize the 
best balance between energy consumption and 
comfort.

8. 

Maintenance

CAUTION

Pay attention to the fan.

 

It is dangerous to inspect the unit while the 
fan is running.
Be sure to turn off the main switch and to 
remove the fuses from the control circuit 
located in the outdoor unit.

8.1 

Maintenance after a long stop period 

(e.g., at the beginning of the season)

•  Check and remove everything that might be 

blocking inlet and outlet vents of indoor units 
and outdoor units.

•  Clean air filters and casings of indoor units.

(b)

 

Refer to the operation manual supplied with the 
indoor units for details on how to proceed and 
make sure to install for details on how to 
proceed and make sure to install cleaned air 
filters back in the same position.

•  Turn on the power at least 6 hours before 

operating the unit in order to ensure smoother 
operation. As soon as the power is turned on, 
the remote controller display appears.

(b) Contact your installer or service person to clean air filters and 

casings of the indoor unit. Maintenance tips and procedures for 
cleaning are provided in the installation/operation manuals of 
dedicated indoor units.

01_EN_3P529409-2B.indd   9

15-Nov-19   3:02:28 PM

Summary of Contents for RZQ180MY1

Page 1: ...SPLIT SYSTEM Air Conditioner OPERATION MANUAL RZQ180MY1 RZQ200MY1 00_CV_3P529409 2B indd 1 30 10 2019 16 48 00...

Page 2: ...occurs After reading the manual keep it in your custody for future reference See also the operation manual included with the indoor unit for details on the indoor unit Store the operation manual inclu...

Page 3: ...very well 11 10 Troubleshooting 11 11 After sales service and warranty 12 11 1 Warranty period 12 11 2 After sales service 12 11 3 Shortening of maintenance cycle and replacement cycle needs to be con...

Page 4: ...ll precautions without fail There are two kinds of safety precaution and tips listed in the following WARNING Failure to follow these instructions properly may result in personal injury or loss of lif...

Page 5: ...f or pull out the supply cord Otherwise an electric shock and injury may result Do not operate the air conditioner with wet hands An electric shock may result Do not place appliances which produce ope...

Page 6: ...ain unit or refrigerant pipes air filter dirt or drain blockage may cause dripping resulting in fouling or failure of the object concerned To avoid oxygen depletion ensure that the room is adequately...

Page 7: ...ck It is not good for your health to expose your body to the air flow for a long time In order to avoid injury do not remove the fan guard of the outdoor unit Do not sit or place objects on the outdoo...

Page 8: ...utlet of the outdoor unit and operating noise do not cause a nuisance to neighbours Be sure there are no obstructions near the air outlet of the outdoor unit Obstructions may result in poor performanc...

Page 9: ...tion stops for removing the heat in the indoor unit The air flow rate may adjust itself depending on the room temperature or the fan may stop immediately This is not a malfunction 6 1 1 For System wit...

Page 10: ...controller shows It may take some time before the fan starts This is not a malfunction INFORMATION The heating capacity drops when the outside temperature falls If this happens use another heating de...

Page 11: ...similar equipment Failing to do so may cause static or distorted pictures Do not place items under the indoor unit they may be damaged by water Condensation may form if the humidity is above 80 or if...

Page 12: ...extremely contaminated the temperature distribution inside a room becomes uneven It is necessary to clean the interior of the indoor unit Ask your dealer for details on cleaning the unit This operati...

Page 13: ...wn below and contact your dealer WARNING Stop operation and turn off the power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electr...

Page 14: ...the air conditioner with manufacturing number if possible and the installation date possibly listed on the warranty card 11 After sales service and warranty 11 1 Warranty period This product includes...

Page 15: ...s Sensor thermistor etc 5 years Remote controller and switches 25 000 hours Drain pan 8 years Expansion valve 20 000 hours Electromagnetic valve 20 000 hours NOTICE 1 Table 1 indicates main components...

Page 16: ...function indoor AF Drain malfunction indoor unit Ah Filter dust chamber malfunction indoor AJ Capacity setting malfunction indoor C1 Transmission malfunction between main PCB and sub PCB indoor C4 Hea...

Page 17: ...yet executed u4 Faulty wiring indoor outdoor u5 Transmission error between remote controller and indoor unit u7 Faulty wiring to Q1 Q2 u8 Abnormal main sub remote controller communication u9 System mi...

Page 18: ...16 NOTE 01_EN_3P529409 2B indd 16 15 Nov 19 3 02 28 PM...

Page 19: ...01_EN_3P529409 2B indd 17 15 Nov 19 3 02 28 PM...

Page 20: ...3P529409 2B M19N102 1911 HT The two dimensional bar code is a manufacturing code 00_CV_3P529409 2B indd 3 30 10 2019 16 48 01...