Installation manual

 

1

 

RZQ7 RZQ100~14 RZQ100~140B8W1B

Split System air conditioners

4PW36243-1A

 

C

 

ONTENTS

 

Page

 

Safety considerations ........................................................................ 1

Before installation.............................................................................. 2

Selecting installation site................................................................... 3

Precautions on installation ................................................................ 4

Installation servicing space ............................................................... 4

Refrigerant pipe size and allowable pipe length ................................ 5

Precautions on refrigerant piping ...................................................... 6

Refrigerant piping.............................................................................. 7

Evacuating......................................................................................... 9

Charging refrigerant ........................................................................ 10

Electrical wiring work....................................................................... 12

Test operation.................................................................................. 13

Disposal requirements .................................................................... 14

Wiring diagram ................................................................................ 15

 

S

 

AFETY

 

 

 

CONSIDERATIONS

 

The precautions listed here are divided into the following two types.
Both cover very important topics, so be sure to follow them carefully.

 

RZQ71B9V3B

RZQ100B8W1B

RZQ100C7V1B

RZQ125B8W1B

RZQ125C7V1B

RZQ140B8W1B

RZQ140C7V1B

 

Split System air conditioners

 

Installation manual

 

READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION. KEEP THIS MANUAL IN A HANDY
PLACE FOR FUTURE REFERENCE.

IMPROPER INSTALLATION OR ATTACHMENT OF
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.

IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DAIKIN DEALER FOR
ADVICE AND INFORMATION.

 

WARNING

 

If the warning is not observed, it may cause 
serious casualties.

 

CAUTION

 

If the caution is not observed, it may cause 
injury or damage to the equipment.

 

WARNING

 

 

For year round cooling applications with low indoor
humidity conditions, such as Electronic Data
Processing rooms, contact your dealer or see the
engineering databook or the service manual.

 

 

For use of air-conditioning units in applications with
temperature alarm settings it is advised to foresee a
delay of 10 minutes for signalling the alarm in case
the alarm temperature is exceeded. The air-
conditioning unit may stop for several minutes during
normal operation for "defrosting of the indoor unit" or
when in "thermostat-stop" operation.

 

WARNING

 

 

Ask your dealer or qualified personnel to carry out
installation work.  Do not install the machine by
yourself.
Improper installation may result in water leakage,
electric shocks or fire.

 

 

Perform installation work in accordance with this
installation manual.
Improper installation may lead to water leakage,
electric shocks or fire.

 

 

Consult your local dealer regarding what to do in case
of refrigerant leakage. When the air conditioner is to
be installed in a small room, it is necessary to take
proper measures so that the amount of any leaked
refrigerant does not exceed the concentration limit in
the event of a leakage. Otherwise, this may lead to an
accident due to oxygen depletion.

 

 

Be sure to use only the specified accessories and
parts for installation work.
Failure to use the specified parts may result in water
leakage, electric shocks, fire, or the unit falling.

 

 

Install the air conditioner on a foundation that can
withstand its weight.
Insufficient strength may result in the fall of equipment
and causing injury.

 

 

Carry out the specified installation work in consideration
of strong winds, typhoons, or earthquakes.
Improper installation work may result in accidents due
to fall of equipment.

 

 

Make certain that all electrical work is carried out by
qualified personnel according to the local laws and
regulations and this installation manual, using a
separate circuit.
Insufficient capacity of the power supply circuit or
improper electrical construction may lead to electric
shocks or fire.

 

 

Make sure that all wiring is secure, using the specified
wires and ensuring that external forces do not act on
the terminal connections or wires.
Incomplete connection or fixing may cause a fire.

 

 

When wiring between the indoor and outdoor units,
and wiring the power supply, form the wires so that
the frontside panel can be securely fastened.
If the frontside panel is not in place, overheat of the
terminals, electric shocks or a fire may be caused.

 

 

If refrigerant gas leaks during installation work,
ventilate the area immediately.
Toxic gas may be produced if refrigerant gas comes
into contact with fire.

 

 

After completing the installation work, check to make
sure that there is no leakage of refrigerant gas.
Toxic gas may be produced if refrigerant gas leaks
into the room and comes into contact with a source of
fire, such as a fan heater, stove or cooker.

 

 

Before touching electric terminal parts, turn off power
switch.

Summary of Contents for RZQ100B8W1B

Page 1: ...INSTALLATION MANUAL RZQ71B9V3B RZQ100C7V1B RZQ125C7V1B RZQ140C7V1B RZQ100B8W1B RZQ125B8W1B RZQ140B8W1B Split System air conditioners ...

Page 2: ... 1 2 4 5 2 4 5 9 7 6 6 8 3 3 1 3 2 4 5 A B A E B C D H H1 L1 H1 H2 L3 L1 L2 H1 H2 L4 L1 L3 L2 H1 H2 L7 L1 L6 L5 L4 L3 L2 A A B2 B2 B2 C C D1 D1 D1 D2 D2 D2 D2 D2 E E H H L1 L1 L1 L2 L2 L2 A A B1 B1 B1 B1 B1 B1 B2 B2 B2 C C D1 D1 D1 D2 D2 D2 D2 D2 E E H H L1 L1 L1 L2 L2 L2 1 1 2 L1 L3 L2 L1 L3 L2 1 2 3 4 5 7 8 9 6 ...

Page 3: ... cu condiţia ca acestea să fie utilizate în conformitate cu instrucţiunile noastre 19 skladni z naslednjimi standardi in drugimi normativi pod pogojem da se uporabljajo v skladu z našimi navodili 20 on vastavuses järgmis t e standardi te ga või teiste normatiivsete dokumentidega kui neid kasutatakse vastavalt meie juhenditele 21 съответстват на следните стандарти или други нормативни документи при...

Page 4: ...hine by yourself Improper installation may result in water leakage electric shocks or fire Perform installation work in accordance with this installation manual Improper installation may lead to water leakage electric shocks or fire Consult your local dealer regarding what to do in case of refrigerant leakage When the air conditioner is to be installed in a small room it is necessary to take prope...

Page 5: ...should be according to national regulations Do not connect the earth wire to gas or water pipes lightning conductor or telephone earth wire Incomplete grounding may cause electric shocks Gas pipe Ignition or explosion may occur if the gas leaks Water pipe Hard vinyl tubes are not effective grounds Lightning conductor or telephone ground wire Electric potential may rise abnormally if struck by a li...

Page 6: ...or evaluating Wondershare PDF Password Remover You can only convert 5 pages with the trial version To get all the pages converted you need to purchase the software from http cbs wondershare com go php pid 526 m db ...

Reviews: