background image

5

WARNING

• It is not good for your health to expose your 

body to the air flow for a long time.

• Ask your dealer for installation of the air con-

ditioner.

Incomplete installation performed by yourself may 
result in a water leakage, electric shock, and fire.

• Ask your dealer for improvement, repair, and 

maintenance.

Incomplete improvement, repair, and maintenance 
may result in a water leakage, electric shock, and fire.

• Improper installation or attachment of equip-

ment or accessories could result in electric 
shock, short-circuit, leaks, fire or other dam-
age to the equipment. Be sure only to use 
accessories made by Daikin which are specifi-
cally designed for use with the equipment and 
have them installed by a professional.

• Ask your dealer to move and reinstall the air 

conditioner.

Incomplete installation may result in a water leak-
age, electric shock, and fire.

• Never let the indoor unit or the remote control-

ler get wet. 

It may cause an electric shock or a fire.

• Never use flammable spray such as hair spray, 

lacquer or paint near the unit.

It may cause a fire.

• Never replace a fuse with that of wrong ampere 

ratings or other wires when a fuse blows out.

Use of wire or copper wire may cause the unit to 
break down or cause a fire.

• Never remove the fan guard of the unit.

A fan rotating at high speed without the fan guard 
is very dangerous.

• Never inspect or service the unit by yourself.

Ask a qualified service person to perform this work.

• Cut off all electric waves before maintenance.

• To avoid the risk of serious electric shock, never 

sprinkle or spill water or liquids on the unit.

• Do not touch the switch with wet fingers.

Touching a switch with wet fingers can cause elec-
tric shock.

• Do not allow children to play on or around the 

unit as they could be injured.

• The heat exchanger fins are sharp enough to 

cut.

To avoid injury wear gloves or cover the fins while 
working around them.

• Do not put a finger or other objects into the air 

inlet or air outlet. The fan is rotating at high 
speed and will cause injury.

• Do not allow children to play on or around the 

unit as they could be injured.

• Operating the air conditioner with wet hands 

could result in a shock hazard.

• Check the unit stand for damage on a continu-

ous basis, especially if it has been in use for a 
long time.

If left in a damaged condition the unit may fall and 
cause injury.

• Placing a flower vase or other containers with 

water or other liquids on the unit could result 
in a shock hazard or fire if a spill occurs.

• Do not touch the air outlet or horizontal blades 

while the swing flap is in operation because 
fingers could get caught and injured.

• Be sure to establish an earth.

Do not earth the unit to a utility pipe, arrester, or 
telephone earth.
Incomplete earth may cause electrical shock, or 
fire.   
A high surge current from lightning or other 
sources may cause damage to the air conditioner.

• Never touch the internal parts of the controller.

Do not remove the front panel because some 
parts inside are dangerous to touch. In addition, 
some parts may be damaged to touching. For 
checking and adjusting internal parts, contact your 
dealer.

CAUTION

• Do not use the air conditioner for other purposes.

In order to avoid any quality deterioration, do not 
use the unit for cooling precision instruments, 
food, plants, animals or works of art.

• Do not place items under the indoor unit which 

may be damaged by water.

Condensation may form if the humidity is above 
80% or if the drain outlet gets blocked.

• Before cleaning, be sure to stop the operation, 

turn the breaker off or pull out the supply cord.

Otherwise, an electric shock and injury may result.

• Never expose little children, plants or animals 

directly to the air flow.

Adverse influence to little children, animals and 
plants may result.

• Do not wash the air conditioner with excessive 

water.

An electric shock or fire may result.

01_EN_3P161360-3D.fm  Page 5  Thursday, April 13, 2006  9:46 AM

Summary of Contents for RXYQ72MTJU

Page 1: ...RXYQ192MTJU REYQ72MTJU REYQ96MTJU REYQ144MTJU REYQ168MTJU REYQ192MTJU Read these instructions carefully before installation Keep this manual in a handy place for future reference This manual should b...

Page 2: ...Figure 1 RXYQ REYQ F NOT AVAILABLE 23 24 Figure 2 Figure 3 F F Figure 4 Figure 5 Figure 6 Figure 7 1 Figure 7 3 Figure 7 2 F F F 00_CV_3P161360 3D fm Page 2 Wednesday April 12 2006 5 25 PM...

Page 3: ...F Figure 8 Figure 9 F F Figure 10 Figure 11 Figure 12 Wall Mounted Multi flow Ceiling Suspended Figure 13 Figure 14 Figure 15 00_CV_3P161360 3D fm Page 3 Wednesday April 12 2006 5 25 PM...

Page 4: ...in the unit or property damage only accidents Keep these warning sheets handy so that you can refer to them if needed Also if this unit is transferred to a new user make sure to hand over this operati...

Page 5: ...er the fins while working around them Do not put a finger or other objects into the air inlet or air outlet The fan is rotating at high speed and will cause injury Do not allow children to play on or...

Page 6: ...r the indoor unit It may cause incomplete combustion or deformation of the unit due to the heat Arrange the drain hose to ensure smooth drainage Incomplete drainage may cause wet ting of the building...

Page 7: ...and or stop time 18 Temperature setting button Use this button for setting the desired tempera ture 19 Filter sign reset button Refer to the operation manual of indoor unit 20 Fan speed control butto...

Page 8: ...tem may control the air flow rate automatically It may take some time to change the air flow rate This is not a malfunction FOR SYSTEMS WITHOUT COOL HEAT SELECTOR Refer to figure 4 Press the operation...

Page 9: ...since the unit uses a hot air circulatory system to warm the entire room If the hot air rises to the ceiling leaving the area above the floor cold we recommend using the circulator the indoor fan for...

Page 10: ...the set time has elapsed Programming the start time The sys tem starts operating after the set time has elapsed The timer can be programmed for a maxi mum of 72 hours The start and the stop time can b...

Page 11: ...CON TROLLER CONTROL SYSTEM This system provides two other control systems beside individual control one remote controller con trols one indoor unit system Confirm which type of your unit is the follo...

Page 12: ...ion See the operation manual included with the indoor unit for details on how to clean it 8 FOLLOWING SYMPTOMS ARE NOT AIR CONDITIONER TROU BLES 8 1 THE SYSTEM DOES NOT OPERATE The air conditioner doe...

Page 13: ...r to heating operation after defrost operation Moisture generated by defrost becomes steam and is exhausted 8 8 NOISE OF AIR CONDITIONERS Indoor unit A zeen sound is heard immediately after the power...

Page 14: ...efer to page 9 9 TROUBLE SHOOTING If one of the following malfunctions occurs take the measures shown below and contact your Daikin dealer WARNING Stop operation and shut off the power if any thing un...

Page 15: ...r unit manual 3 The system operates but cooling or heating is insufficient Check if air inlet or outlet of outdoor or indoor unit is blocked by obstacles Remove any obstacle and make it well ventilate...