TROUBLE SHOOTING

TROUBLE SHOOTING

Trouble Shooting

These cases are not troubles.

The following cases are not air conditioner troubles but have some reasons. You may just continue using it.

Case

Explanation

Does not operate at all.

• 

Check if the fuse has blown. 

Set power switch to off.

• 

Check if breaker has worked. 

Turn the power on with the breaker switch in the 

off position. 

Do not turn the power on with the breaker switch in the trip position. 

(Contact your dealer.)

• 

When the power is interrupted. 

Wait until the power is recovered, then operate the air conditioner again. 

The air conditioner automatically resumes operation in about 3 minutes. 

You should just wait for a while.

Operation does not start soon.

• 

When ON/OFF button was pressed 

soon after operation was stopped.

• 

When the mode was reselected.

• 

This is to protect the air conditioner. 

You should wait for about 5 minutes. 

(The microcomputer is preparing for operation. Wait for about 10 minutes.)

Hot air does not flow out soon after 

the power supply is turned on.

• 

The air conditioner is warming up. You should wait for about 1 minute. (The system 

is designed to start discharging air only after it has reached a certain temperature.)

The heating operation stops suddenly 

and a flowing sound is heard.

• 

The system is taking away the frost on the outdoor unit. 

You should wait for about 3 to 8 minutes. (Max. 10 minutes).

• 

This sound indicates that the valve for the refrigerant bypass is in operation.

A “Zeen” sound is heard immediately 

after the power supply is turned on.

• 

The electronic expansion* valve inside an indoor unit starts working and 

makes the noise. Its volume will reduce in about one minute. 

*  Electronic expansion valve … Controls the flow rate of the gas 

(refrigerant) flowing inside the indoor unit.

A continuous low “Shah” sound is 

heard when the system is in cooling 

operation or at a stop.

• 

When the drain pump (optional accessories) is in operation, this noise is 

heard.

A “Pishi-pishi” squeaking sound is 

heard when the system stops after 

heating operation.

• 

Expansion and contraction of plastic parts caused by temperature change 

makes this noise.

A low “Sah”, “Choro-choro” sound is 

heard while an indoor unit has stopped.

• 

When the other indoor unit is in operation, this noise is heard. In order to prevent oil and 

refrigerant from remaining in the system, a small amount of refrigerant is kept flowing.

A continuous low “Shuh” sound is 

heard when the systems is in cooling 

or defrost operation.

• This is the sound of refrigerant gas flowing through both indoor and 

outdoor units.

A “Shuh” sound which is heard at the start 

or immediately after the stop of operation 

or which is heard at the start or immediately 

after the stop of defrost operation.

• This is the noise of refrigerant caused by flow stop and flow change.

When the tone of operating noise changes.

• 

This noise caused by the change of frequency.

A continuous “shuh” sound generated 

during operation or immediately after 

the operation is started or stopped.

• 

This sound indicates that the valve for the refrigerant bypass is in operation.

The outdoor unit emits water or steam.

 

„

In heating mode

• 

The frost on the outdoor unit melts into water or steam when the air 

conditioner is in defrost operation.

 

„

In cooling or dry mode

• 

Moisture in the air condenses into water on the cool surface of outdoor 

unit piping and drips.

Mists come out of the indoor unit.

• 

This happens when the air in the room is cooled into mist by the cold 

airflow during cooling operation.

• 

If the inside of an indoor unit is extremely contaminated, the temperature 

distribution inside a room becomes uneven. It is necessary to clean the 

inside of the indoor unit. Ask your Daikin dealer for details on cleaning the 

indoor unit. This operation requires a qualified service person.

ON

Switch

Trip position

OFF

Breaker

01_EN_3P344160-13U.indd   14

06-Oct-20   2:42:06 PM

Summary of Contents for RXYMQ5BVM

Page 1: ...OPERATION MANUAL System air conditioner RXYMQ5BVM RXYMQ6BVM 00_CV_3P344160 13U indd 1 23 08 2020 14 09 18...

Page 2: ...00_CV_3P344160 13U indd 2 23 08 2020 14 09 18...

Page 3: ...t away for future reference CONTENTS READ BEFORE OPERATION Safety precaution 1 Names of parts 4 Preparation Before Operation 6 Useful Information 6 OPERATION Cooling Heating Fan Operation 7 Program Dr...

Page 4: ...ocal dealer regarding modification repair and maintenance of the air conditioner Improper workmanship may result in water leakage electric shocks or fire hazards Do not place objects including rods yo...

Page 5: ...lvents may cause crack damage to the product electric shocks or fire Be sure to use a dedicated power supply for the air conditioner The use of any other power supply may cause heat generation fire or...

Page 6: ...itioner when using a room fumigation type insecticide Fumigation chemicals deposited in the unit could endanger the health of those who are hypersensitive to such chemicals Do not place objects in dir...

Page 7: ...Also pay attention to operating noise Select the following kinds of location a A place that can sufficiently withstand the weight of the air conditioner with less running noises and vibrations b A pla...

Page 8: ...le the backlight is lit Excluding the ON OFF button If 2 remote controllers are used to control a single indoor unit the backlight of the remote controller accessed first will be lit Use to select the...

Page 9: ...the air conditioner for a long time Do not leave the door or window open The air will be released and the effect of cooling heating will be reduced Do not allow direct sunshine to enter the room duri...

Page 10: ...llows Cooling Operation Heating Operation Fan Operation 2 Press ON OFF button Operation lamp lights up and the system starts operation ADJUSTMENT 3 Press temperature setting button and program the set...

Page 11: ...e air conditioner is controlled so that excessive load is not applied 1 Defrost operation As the frost on the coil of an outdoor unit increase heating effect decreases and the system goes into defrost...

Page 12: ...rature is 16 C or lower BRC1E62 2 4 1 Press mode selector button several times and select Program Dry Operation 2 Press ON OFF button Operation lamp lights up and system starts operation ADJUSTMENT 3...

Page 13: ...suspended or a wall mounted unit the microcomputer may control the flow direction and then the user interface indication will also change When room temperature is higher than the set temperature At d...

Page 14: ...Off Timer screen 6 Press buttons to set the time from operation start until the unit automatically stops Selections can be made in increments of 10 minutes from 30 to 180 minutes Holding down the butt...

Page 15: ...controller can select the cooling heating operation mode One of these remote controllers needs to be designated as the master remote controller When one outdoor unit is connected with several indoor u...

Page 16: ...1 When master remote controller in which is not displayed is set to cooling or heating Other slave remote controllers in which is displayed The operation mode is changed over to the mode selected in t...

Page 17: ...cooling operation or at a stop When the drain pump optional accessories is in operation this noise is heard A Pishi pishi squeaking sound is heard when the system stops after heating operation Expansi...

Page 18: ...This is to prevent oil and refrigerant from remaining in the compressor The unit will stop after 5 to 10 minutes The inside of an outdoor unit is warm when the unit has stopped This is because the cra...

Page 19: ...k at all Blown fuse or open breaker Replace the fuse or close the breaker Power outage If the main power supply is turned off during operation operation will restart automatically after power turns ba...

Page 20: ...sed in the air conditioner is safe and does not leak usually If the refrigerant leaks into the room and becomes contact with burning appliances such as fan heater stove and cooker however harmful gase...

Page 21: ...18 TROUBLE SHOOTING NOTES 01_EN_3P344160 13U indd 18 06 Oct 20 2 42 07 PM...

Page 22: ...19 TROUBLE SHOOTING NOTES 01_EN_3P344160 13U indd 19 06 Oct 20 2 42 07 PM...

Page 23: ...01_EN_3P344160 13U indd 20 06 Oct 20 2 42 07 PM...

Page 24: ...3P344160 13U M20N083 2010 HT The two dimensional bar code is a manufacturing code The two dimensional bar code is a manufacturing code 00_CV_3P344160 13U indd 3 23 08 2020 14 09 19...

Reviews: