background image

RXYCQ8~20A7Y1B

VRV Classic System air conditioner

4P327539-1 — 2012.08

Operation manual

5

7.4.

Setting the master remote controller

When the system is installed as shown in 

figure 4

 (RXYCQ outdoor

unit is connected to several indoor units). it is necessary to
designate one of the remote controllers as the master remote
controller.

Only the master remote controller can select heating or cooling.

The displays of slave remote controllers show 

 (change-

over under centralized control) and slave remote controllers
automatically follow the operation mode directed by the master
remote controller.

However, it is possible to changeover to program dry with slave
remote controllers if the system is in cooling operation set by the
master remote controller.

How to designate the master remote controller

1

Press the operation mode selector button of the current master
remote controller for 4 seconds.

The display showing 

 (change-over under centralized

control) of all slave remote controllers connected to the same
outdoor unit or BS unit flash.

2

Press the operation mode selector button of the controller that
you wish to designate as the master remote controller. Then
designation is completed. This remote controller is designated
as the master remote controller and the display showing 
(change-over under centralized control) vanishes.

The displays of other remote controllers show 

 (change-

over under centralized control).

7.5.

Precautions for group control system or two 
remote controller control system

This system provides two other control systems beside individual
control (one remote controller controls one indoor unit) system.
Confirm the following if your unit is of the following control system
type.

Group control system
One remote controller controls up to 16 indoor units. All indoor
units are equally set.

Two remote controller control system
Two remote controllers control one indoor unit (in case of group
control system, one group of indoor units). The unit is
individually operated.

8.

E

NERGY

 

SAVING

 

AND

 

OPTIMUM

 

OPERATION

Observe the following precautions to ensure the system operates
properly.

Adjust the air outlet properly and avoid direct air flow to room
inhabitants.

Adjust the room temperature properly for a comfortable
environment. Avoid excessive heating or cooling.

Prevent direct sunlight from entering a room during cooling
operation by using curtains or blinds.

Ventilate often.
Extended use requires special attention to ventilation.

Keep doors and windows closed. If the doors and windows
remain open, air will flow out of your room causing a decrease in
the cooling or heating effect.

Be careful not to cool or heat too much. To save energy, keep the
temperature setting at a moderate level.

Never place objects near the air inlet or the air outlet of the unit.
It may cause deterioration in the effect or stop the operation.

Turn off the main power supply switch to the unit when the unit is
not used for longer periods of time. If the switch is on, it uses
electricity. Before restarting the unit, turn on the main power
supply switch 6 hours before operation to ensure smooth
running. (Refer to "Maintenance" in the indoor unit manual.)

When the display shows 

 (time to clean the air filter), ask a

qualified service person to clean the filters. (Refer to
"Maintenance" in the indoor unit manual.)

Keep the indoor unit and remote control at least 1 m away from
televisions, radios, stereos, and other similar equipment.
Failing to do so may cause static or distorted pictures.

Do not place items under the indoor unit which may be damaged
by water.
Condensation may form if the humidity is above 80% or if the
drain outlet gets blocked.

9.

M

AINTENANCE

9.1.

Maintenance after a long stop period 

(e.g. at the

beginning of the season)

Check and remove everything that might be blocking inlet and
outlet vents of indoor units and outdoor units.

Clean air filters and casings of indoor units. Refer to the
operation manual supplied with the indoor units for details on
how to proceed and make sure to install cleaned air filters back
in the same position.

Turn on the power at least 6 hours before operating the unit in
order to ensure smoother operation. As soon as the power is
turned on, the remote controller displays appear.

NOTE

Contact your dealer in case of changing the
combination or setting of group control and two remote
controller control systems.

Recommended temperature setting

For cooling

26~28°C

For heating

20~24°C

Pay attention to the fan.

It is dangerous to inspect the unit while the fan is running.
Be sure to turn off the main switch and to remove the fuses
from the control circuit located in the outdoor unit.

Summary of Contents for RXYCQ8A7Y1B

Page 1: ...VRV Classic System air conditioner OPERATION MANUAL RXYCQ8A7Y1B RXYCQ10A7Y1B RXYCQ12A7Y1B RXYCQ14A7Y1B RXYCQ16A7Y1B RXYCQ18A7Y1B RXYCQ20A7Y1B System air conditioner...

Page 2: ...6 1 6 2 6 3 5 1 2 7 9 2 4 1 3 8 UNIT NO 1 2 3 4 2 1 2 3 C D A B 4 1 5 5 3 3 3 4 6 4 1 1 1 1 1 1 1 1 2 4 2 3 2 3 2 3 3 5 2 2 2 1 2 3 4 6 2 6 3 5 6 1 8 9 7...

Page 3: ...n electric shock or a re Never use a ammable spray such as hair spray lacquer or paint near the unit It may cause a re Never touch the air outlet or the horizontal blades while the swing ap is in oper...

Page 4: ...ic shock or re make sure that an earth leak detector is installed Be sure the air conditioner is electrically earthed In order to avoid electric shock make sure that the unit is grounded and that the...

Page 5: ...ay change over under centralized control ashes refer to 7 4 Setting the master remote controller on page 5 The fan may keep on running for about 1 minute after the heating operation stops The air ow r...

Page 6: ...ection adjust button Only for Double ow Multi ow Corner Ceiling suspended and Wall mounted Refer to 7 3 Adjusting the air ow direction on page 4 for details Stopping the system 5 Press the on off butt...

Page 7: ...erly for a comfortable environment Avoid excessive heating or cooling Prevent direct sunlight from entering a room during cooling operation by using curtains or blinds Ventilate often Extended use req...

Page 8: ...the remote control display The fan direction does not swing This is because the unit is being controlled by the micro computer Symptom 6 White mist comes out of a unit Symptom 6 1 Indoor unit When hu...

Page 9: ...clean the air lter Refer to Maintenance in the indoor unit manual 3 The system operates but cooling or heating is insuf cient Check if air inlet or outlet of outdoor or indoor unit is not blocked by o...

Page 10: ...Contact your dealer In case of accidental refrigerant leaks make sure there are no naked ames The refrigerant itself is entirely safe non toxic and non combustible but it will generate toxic gas when...

Page 11: ......

Page 12: ...4P327539 1 2012 08 Copyright 2012 Daikin...

Reviews: