Cautions

Do not use the air conditioner for other purposes.
In order to avoid any quality deterioration, do not use the unit for
cooling precision instruments, food, plants, animals or works of
art.

In order to avoid injury, do not remove the fan guard of the
outdoor unit.

To avoid oxygen deficiency, ventilate the room sufficiently if
equipment with burner is used together with the air conditioner.

After a long use, check the unit stand and fitting for damage.
If damaged, the unit may fall and result in injury.

Do not place a flammable spray bottle near the air conditioner
and do not use sprays.
Doing so may result in a fire.

Before cleaning, be sure to stop the operation, turn the breaker
off or pull out the supply cord.
Otherwise, an electric shock and injury may result.

Do not operate the air conditioner with a wet hand.
An electric shock may result.

Do not place items which might be damaged by moisture under
the indoor unit.
Condensation may form if the humidity is above 80%, if the drain
outlet is blocked or the filter is polluted.

Do not place appliances which produce open fire in places
exposed to the air flow from the unit or under the indoor unit. It
may cause incomplete combustion or deformation of the unit
due to the heat.

Do not allow anyone to mount on the outdoor unit or avoid
placing any object on it.
Falling or tumbling may result in injury.

Never expose little children, plants or animals directly to the air
flow.
Adverse influence to little children, animals and plants may
result.

Do not wash the air conditioner with water.
Electric shock or fire may result.

This appliance is not intended for use by persons, including
children, with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance
by a person responsible for their safety.

Do not install the air conditioner at any place where flammable
gas may leak out.
If the gas leaks out and stays around the air conditioner, a fire
may break out.

In order to avoid electric shock or fire, make sure that an earth
leak detector is installed.

Be sure the air conditioner is electrically earthed.
In order to avoid electric shock, make sure that the unit is
grounded and that the earth wire is not connected to gas or
water pipe, lightning conductor or telephone earth wire.

Arrange the drain hose to ensure smooth drainage. Incomplete
drainage may cause wetting of the building, furniture etc.

Do not let children play on and around the outdoor unit.
If they touch the unit carelessly, it may result in injury.

Do not place a flower vase or anything containing water on the
unit.
Water may enter the unit, causing an electric shock or fire.

Do not place the controller exposed to direct sunlight.
The LCD display may get discolored, failing to display the data.

Do not wipe the controller operation panel with benzine, thinner,
chemical dustcloth, etc.
The panel may get discolored or the coating peeled off. If it is
heavily dirty, soak a cloth in water-diluted neutral detergent,
squeeze it well and wipe the panel clean. Wipe it with another
dry cloth.

Never touch the internal parts of the controller.
Do not remove the front panel. Some parts inside are dangerous
to touch and a machine trouble may happen. For checking and
adjusting the internal parts, contact your dealer.

Avoid placing the controller in a spot splashed with water.
Water coming inside the machine may cause an electric leak or
may damage the internal electronic parts.

Do not operate the air conditioner when using a room
fumigation-type insecticide.
Failure to observe could cause the chemicals to become
deposited in the unit, which could endanger the health of those
who are hypersensitive to chemicals.

Do not touch the heat exchanger fins.
These fins are sharp and could result in cutting injuries.

The appliance is not intended for use by young children or infirm
persons without supervision.

Young children should be supervised to ensure that they do not
play with the appliance.

2.

I

MPORTANT

 

INFORMATION

 

REGARDING

 

THE

 

REFRIGERANT

 

USED

This product contains fluorinated greenhouse gases covered by the
Kyoto Protocol.

Refrigerant type:

R410A

GWP

(1)

 value:

1975

(1)

 GWP = global warming potential

Periodical inspections for refrigerant leaks may be required
depending on European or local legislation. Please contact your local
dealer for more information.

Summary of Contents for RXYCQ8A7Y1B

Page 1: ...VRV Classic System air conditioner OPERATION MANUAL RXYCQ8A7Y1B RXYCQ10A7Y1B RXYCQ12A7Y1B RXYCQ14A7Y1B RXYCQ16A7Y1B RXYCQ18A7Y1B RXYCQ20A7Y1B System air conditioner...

Page 2: ...6 1 6 2 6 3 5 1 2 7 9 2 4 1 3 8 UNIT NO 1 2 3 4 2 1 2 3 C D A B 4 1 5 5 3 3 3 4 6 4 1 1 1 1 1 1 1 1 2 4 2 3 2 3 2 3 3 5 2 2 2 1 2 3 4 6 2 6 3 5 6 1 8 9 7...

Page 3: ...n electric shock or a re Never use a ammable spray such as hair spray lacquer or paint near the unit It may cause a re Never touch the air outlet or the horizontal blades while the swing ap is in oper...

Page 4: ...ic shock or re make sure that an earth leak detector is installed Be sure the air conditioner is electrically earthed In order to avoid electric shock make sure that the unit is grounded and that the...

Page 5: ...ay change over under centralized control ashes refer to 7 4 Setting the master remote controller on page 5 The fan may keep on running for about 1 minute after the heating operation stops The air ow r...

Page 6: ...ection adjust button Only for Double ow Multi ow Corner Ceiling suspended and Wall mounted Refer to 7 3 Adjusting the air ow direction on page 4 for details Stopping the system 5 Press the on off butt...

Page 7: ...erly for a comfortable environment Avoid excessive heating or cooling Prevent direct sunlight from entering a room during cooling operation by using curtains or blinds Ventilate often Extended use req...

Page 8: ...the remote control display The fan direction does not swing This is because the unit is being controlled by the micro computer Symptom 6 White mist comes out of a unit Symptom 6 1 Indoor unit When hu...