background image

English

11

Wiring

Wiring diagram

Wiring diagram parts table

:

Terminal strip

:

Field wiring

:

Connector

:

Terminal

:

Connection

BLK

:

Black

ORG

:

Orange

BLU

:

Blue

RED

:

Red

BRN

:

Brown

WHT

:

White

GRN

:

Green

YLW

:

Yellow

Notes

:

Refer to the nameplate of the unit for power requirements.

:

OUTDOOR

Outdoor

:

CONDENSER

Condenser

:

DISCHARGE

Discharge

C400,C405 ............ Capacitor
DB1........................ Diode bridge
E1,E2,HL1,HN1,
HR1,HR2,MR30_A,
MR30_B................. Connection
E1H........................ Heater
FU1,FU2,FU3 ........ Fuse
IPM1 ...................... Intelligent power module
L............................. Live
L1........................... Coil
L1R ........................ Reactor
M1C ....................... Compressor motor
M1F ....................... Fan motor
MR30,MRCW, 
MRM10 .................. Magnetic relay

N ............................ Neutral
PCB1 ..................... Printed circuit board
PS .......................... Power supply
Q1L ........................ Overload protector
R1T,R2T,R3T ......... Thermistor
S20,S30,S40,S50,
S71,S80,S90.......... Connector
SA1 ........................ Surge arrestor
V2,V3,V150............ Varistor
X1M ....................... Terminal strip
X12A ...................... Power suspend
Y1E ........................ Electronic expansion valve coil
Y1R........................ Reversing solenoid valve coil
Z1C,Z2C,Z3C ........ Ferrite core

....................... Protective earth

Summary of Contents for RXS25L3V1B

Page 1: ...ion S rie split R410A Fran ais Montagehandleiding R410A Split systeem Nederlands Manual de instalaci n Serie Split R410A Espa ol Manuale d installazione Serie Multiambienti R410A Italiano R410A Manual...

Page 2: ...lorado positivamente por B de acuerdo con el Certificado C 06 Nota delineato nel A e giudicato positivamente da B secondo il Certificato C 07 A B C 08 Nota tal como estabelecido em A e com o parecer p...

Page 3: ...ormal heat build up or fire When wiring the power supply and connecting the wiring between the indoor and outdoor units position the wires so that the control box lid can be securely fastened Improper...

Page 4: ...m ceiling or stacked CAUTION When operating the air conditioner in a low outdoor ambient temperature be sure to follow the instructions described below To prevent exposure to wind install the outdoor...

Page 5: ...the stop valve cover Remove the screw on the stop valve cover Slide the lid downward to remove it How to attach the stop valve cover Insert the upper part of the stop valve cover into the outdoor uni...

Page 6: ...foundation surface Outdoor Unit Installation 1 Installing outdoor unit 1 When installing the outdoor unit refer to Precautions for Selecting the Location and the Outdoor Unit Installation Drawings 2...

Page 7: ...orque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leakage Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand Then tighten them ful...

Page 8: ...hes 110 C max Choose heat insulation materials that will withstand this temperature 2 Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below 3 Use separate th...

Page 9: ...of charging hose which comes from gauge manifold to gas stop valve s service port 2 Fully open gauge manifold s low pressure valve Lo and completely close its high pressure valve Hi High pressure valv...

Page 10: ...valve cover 3 Disconnect the selective connector for standby electricity saving 4 Turn on the main power supply CAUTION Before connecting or disconnecting the selective connector for standby electrici...

Page 11: ...e liquid stop valve close the gas stop valve within 3 minutes then stop the forced cooling operation Facility Setting cooling at low outdoor temperature This function is designed for facilities such a...

Page 12: ...block Observe the notes mentioned below when wiring to the power supply terminal block Precautions to be taken for power supply wiring CAUTION When connecting the connection wires to the terminal blo...

Page 13: ...B1 Diode bridge E1 E2 HL1 HN1 HR1 HR2 MR30_A MR30_B Connection E1H Heater FU1 FU2 FU3 Fuse IPM1 Intelligent power module L Live L1 Coil L1R Reactor M1C Compressor motor M1F Fan motor MR30 MRCW MRM10 M...

Page 14: ...a small amount of power in its standby mode If the system is not to be used for some time after installation shut off the circuit breaker to eliminate unnecessary power consumption If the circuit brea...

Page 15: ......

Page 16: ...3P381941 1 2014 06 Copyright 2014 Daikin...

Reviews: