![background image](http://html1.mh-extra.com/html/daikin/rxr28ev1b9/rxr28ev1b9_service-manual-removal-procedure_2459936026.webp)
Removal of PCB
Si00-777
24
Removal Procedure
7
Remove the PCB from
the electrical box.
8
Disconnect the
connectors.
S20 : electronic expansion
valve coil
S21 : humidifying rotor motor
S22 : damper motor
S45 : thermal fuse
S70 : fan motor
S72 : humidifier fan motor
S80 : four way valve coil
S90 : thermistor assembly
S91 : humidifying thermistor
S501: limit switch
Step
Procedure
Points
(R5867)
(R14168)
S20 S80 S21S72
S70 S90S91
S45
S22
S501