Removal of Electrical Box
Si00-777
20
Removal Procedure
9
Disconnect the relay
harness for the
compressor.
10
Remove the screw of
the terminal board.
Thermal fuse should be
replaced with the terminal
board.
You can work without
removing the terminal
board.
11
Remove the screws
and disconnect the
connecting wires and
the power supply
cables.
Step
Procedure
Points
(R14010)
(R14052)
(R14054)