background image

7 Technical data

Installation manual

11

(A)RXP20~35M5V1B
R32 split series
3P519299-5B – 2018.12

7

Technical data

subset

  of  the  latest  technical  data  is  available  on  the  regional  Daikin  website  (publicly  accessible).  The 

full  set

  of  latest  technical  data  is

available on the Daikin Business Portal (authentication required).

7.1

Wiring diagram

,

A

INDOOR

OUTDOOR

For applied parts and numbering, refer to the wiring diagram on the unit. Part numbering is by Arabic numbers in ascending order for each part 

and is represented in the overview below by symbol “*” in the part code.

Unified Wiring Diagram Legend

CIRCUIT BREAKER

: CONNECTION

: CONNECTOR

: EARTH

FIELD WIRING

: FUSE

INDOOR UNIT

OUTDOOR UNIT

PROTECTIVE EARTH

PROTECTIVE EARTH (SCREW)

: RECTIFIER

RELAY CONNECTOR

SHORT-CIRCUIT CONNECTOR

: TERMINAL

TERMINAL STRIP

WIRE CLAMP

WHT : WHITE
YLW : YELLOW

PNK 

: PINK

PRP, PPL :  PURPLE
RED  : RED

GRN : GREEN
GRY : GREY
ORG : ORANGE

BLK  : BLACK
BLU  : BLUE
BRN : BROWN

A*P 

PRINTED CIRCUIT BOARD

BS* 

PUSHBUTTON ON/OFF, OPERATION SWITCH

BZ, H*O 

BUZZER

C* 

: CAPACITOR

AC*, CN*, E*, HA*, HE*, HL*, HN*, : 

CONNECTION, CONNECTOR

HR*, MR*_A, MR*_B, S*, U, V,
W, X*A, K*R_*
D*, V*D 

DIODE

DB* 

DIODE BRIDGE

DS* 

DIP SWITCH

E*H 

: HEATER

F*U, FU* (FOR CHARACTERISTICS,  :  FUSE
REFER TO PCB INSIDE YOUR UNIT)
FG* 

CONNECTOR (FRAME GROUND)

H* 

: HARNESS

H*P, LED*, V*L 

PILOT LAMP, LIGHT EMITTING DIODE

HAP 

LIGHT EMITTING DIODE (SERVICE MONITOR GREEN)

HIGH VOLTAGE 

HIGH VOLTAGE

IES 

INTELLIGENT EYE SENSOR

IPM* 

INTELLIGENT POWER MODULE

K*R, KCR, KFR, KHuR, K*M 

MAGNETIC RELAY

: LIVE

L* 

: COIL

L*R 

: REACTOR

M* 

STEPPER MOTOR

M*C 

COMPRESSOR MOTOR

M*F 

FAN MOTOR

M*P 

DRAIN PUMP MOTOR

M*S 

SWING MOTOR

MR*, MRCW*, MRM*, MRN* 

MAGNETIC RELAY

: NEUTRAL

n=*, N=* 

NUMBER OF PASSES THROUGH FERRITE CORE

PAM 

PULSE-AMPLITUDE MODULATION

PCB* 

PRINTED CIRCUIT BOARD

PM* 

POWER MODULE

PS 

SWITCHING POWER SUPPLY

PTC* 

THERMISTOR PTC

Q* 

INSULATED GATE BIPOLAR TRANSISTOR 
(IGBT)

Q*DI 

EARTH LEAK CIRCUIT BREAKER

Q*L 

OVERLOAD PROTECTOR

Q*M 

THERMO SWITCH

R* 

: RESISTOR

R*T 

: THERMISTOR

RC 

: RECEIVER

S*C 

LIMIT SWITCH

S*L 

FLOAT SWITCH

S*NPH 

PRESSURE SENSOR (HIGH)

S*NPL 

PRESSURE SENSOR (LOW)

S*PH, HPS* 

PRESSURE SWITCH (HIGH)

S*PL 

PRESSURE SWITCH (LOW)

S*T 

: THERMOSTAT

S*RH 

HUMIDITY SENSOR

S*W, SW* 

OPERATION SWITCH

SA*, F1S 

SURGE ARRESTOR

SR*, WLU 

SIGNAL RECEIVER

SS* 

SELECTOR SWITCH

SHEET METAL  : 

TERMINAL STRIP FIXED PLATE

T*R 

: TRANSFORMER

TC, TRC 

TRANSMITTER

V*, R*V 

VARISTOR

V*R 

DIODE BRIDGE

WRC 

WIRELESS REMOTE CONTROLLER

X* 

: TERMINAL

X*M 

TERMINAL STRIP (BLOCK)

Y*E 

ELECTRONIC EXPANSION VALVE COIL

Y*R, Y*S 

REVERSING SOLENOID VALVE COIL

Z*C 

FERRITE CORE

ZF, Z*F 

NOISE FILTER

Summary of Contents for RXP25M5V1B

Page 1: ...Installation manual R32 split series English Installation manual R32 split series RXP20M5V1B RXP25M5V1B RXP35M5V1B ARXP20M5V1B ARXP25M5V1B ARXP35M5V1B...

Page 2: ...ka emiau nurodytus standartus ir arba kitus norminius dokumentus su s lyga kad yra naudojami pagal m s nurodymus tad ja lietoti atbilsto i ra ot ja nor d jumiem atbilst sekojo iem standartiem un citie...

Page 3: ...9 4 6 2 To connect the electrical wiring on the outdoor unit 9 4 7 Finishing the outdoor unit installation 9 4 7 1 To finish the outdoor unit installation 9 4 7 2 To close the outdoor unit 9 5 Commis...

Page 4: ...stall a baffle plate when the air outlet is exposed to wind It is recommended to install the outdoor unit with the air inlet facing the wall and NOT directly exposed to the wind b a b c a Baffle plate...

Page 5: ...12 m 3 2 3 Refrigerant piping insulation Pipe outer diameter p Insulation inner diameter i Insulation thickness t 6 4 mm 1 4 8 10 mm 10 mm 9 5 mm 3 8 12 15 mm i i t p p If the temperature is higher t...

Page 6: ...necting the refrigerant piping involves Connecting the refrigerant piping to the indoor unit Connecting the refrigerant piping to the outdoor unit Insulating the refrigerant piping Keeping in mind the...

Page 7: ...recharging refrigerant Example When relocating the system After a leak Charging additional refrigerant Before charging additional refrigerant make sure the outdoor unit s external refrigerant piping i...

Page 8: ...2 Charge the additional refrigerant amount 3 Open the gas stop valve 4 5 6 To fix the fluorinated greenhouse gases label 1 Fill in the label as follows b Contains fluorinated greenhouse gases 2 1 1 1...

Page 9: ...E NEVER operate the unit without thermistors and or pressure sensors switches Burning of the compressor might result 5 1 Checklist before commissioning After the installation of the unit first check t...

Page 10: ...T use the unit s automatic pump down function with which you can collect all refrigerant from the system into the outdoor unit Possible consequence Self combustion and explosion of the compressor beca...

Page 11: ...TER F U FU FOR CHARACTERISTICS FUSE REFER TO PCB INSIDE YOUR UNIT FG CONNECTOR FRAME GROUND H HARNESS H P LED V L PILOT LAMP LIGHT EMITTING DIODE HAP LIGHT EMITTING DIODE SERVICE MONITOR GREEN HIGH VO...

Page 12: ...MA S STEMLER SAN T C A K kbakkalk y Mah Kay da Cad No 1 Kat 21 22 34750 Ata ehir STANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr 3P519299 5B 2018 12...

Reviews: