background image

Table of contents

Installation manual

3

(A)RXP20~35M5V1B
R32 split series
3P650253-6E – 2022.04

Table of contents

1 About the documentation

3

1.1

About this document..................................................................

3

2 Specific installer safety instructions

3

3 About the box

5

3.1

Outdoor unit...............................................................................

5

3.1.1

To unpack the outdoor unit .........................................

5

3.1.2

To remove the accessories from the outdoor unit.......

6

4 Unit installation

6

4.1

Preparing the installation site ....................................................

6

4.1.1

Installation site requirements of the outdoor unit ........

6

4.1.2

Additional installation site requirements of the
outdoor unit in cold climates .......................................

6

4.2

Opening the units ......................................................................

6

4.2.1

To open the outdoor unit.............................................

6

4.3

Mounting the outdoor unit..........................................................

7

4.3.1

To provide the installation structure ............................

7

4.3.2

To install the outdoor unit............................................

7

4.3.3

To provide drainage ....................................................

7

4.3.4

To prevent the outdoor unit from falling over ..............

7

5 Piping installation

8

5.1

Preparing refrigerant piping .......................................................

8

5.1.1

Refrigerant piping requirements..................................

8

5.1.2

Refrigerant piping length and height difference ..........

8

5.1.3

Refrigerant piping insulation .......................................

8

5.2

Connecting the refrigerant piping ..............................................

8

5.2.1

About connecting the refrigerant piping ......................

8

5.2.2

Precautions when connecting the refrigerant piping ...

8

5.2.3

To connect the refrigerant piping to the outdoor unit ..

8

5.3

Checking the refrigerant piping .................................................

8

5.3.1

To check for leaks.......................................................

8

5.3.2

To perform vacuum drying ..........................................

9

6 Charging refrigerant

9

6.1

About charging refrigerant.........................................................

9

6.2

About the refrigerant..................................................................

9

6.3

To determine the additional refrigerant amount ........................

10

6.4

To determine the complete recharge amount ...........................

10

6.5

To charge additional refrigerant ................................................

10

6.6

To fix the fluorinated greenhouse gases label...........................

10

7 Electrical installation

10

7.1

Specifications of standard wiring components ..........................

11

7.2

To connect the electrical wiring to the outdoor unit ...................

11

8 Finishing the outdoor unit installation

11

8.1

To finish the outdoor unit installation.........................................

11

8.2

To close the outdoor unit...........................................................

11

9 Maintenance and service

11

10 Commissioning

11

10.1

Checklist before commissioning ................................................

11

10.2

Checklist during commissioning ................................................

12

10.3

To perform a test run .................................................................

12

10.4

Starting up the outdoor unit .......................................................

12

11 Disposal

12

11.1

Overview: Disposal....................................................................

12

11.2

To pump down...........................................................................

12

11.3

To start and stop forced cooling ................................................

13

11.3.1

To start and stop forced cooling using the indoor unit
ON/OFF switch ........................................................... 13

11.3.2

To start and stop forced cooling using the indoor unit
user interface .............................................................. 13

12 Technical data

14

12.1

Wiring diagram ........................................................................... 14

12.1.1

Unified wiring diagram legend...................................... 14

12.2

Piping diagram ........................................................................... 16

12.2.1

Piping diagram: Outdoor unit ....................................... 16

1

About the documentation

1.1

About this document

INFORMATION

Make sure that the user has the printed documentation and
ask him/her to keep it for future reference.

Target audience

Authorised installers

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you MUST read before installing

▪ Format: Paper (in the box of the outdoor unit)

Outdoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the outdoor unit)

Installer reference guide:

▪ Preparation of the installation, reference data, …

▪ Format:  Digital  files  on 

https://www.daikin.eu

.  Use  the  search

function   to find your model.

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

Business Portal (authentication required).

2

Specific installer safety
instructions

Always observe the following safety instructions and regulations.

Unit installation (see 

"4 Unit installation"

 [

4

 6])

WARNING

Installation  shall  be  done  by  an  installer,  the  choice  of
materials  and  installation  shall  comply  with  the  applicable
legislation. In Europe, EN378 is the applicable standard.

WARNING

The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating  ignition  sources  (e.g.  open  flames,  an  operating
gas  appliance,  or  an  operating  electric  heater).  The  room
size shall be as specified in the General safety precaution.

Summary of Contents for RXP20M5V1B

Page 1: ...Installation manual R32 split series English Installation manual R32 split series RXP20M5V1B RXP25M5V1B RXP35M5V1B ARXP20M5V1B ARXP25M5V1B ARXP35M5V1B...

Page 2: ...nka emiau nurodytus standartus ir arba kitus norminius dokumentus su s lyga kad yra naudojami pagal m s nurodymus tad ja lietoti atbilsto i ra ot ja nor d jumiem atbilst sekojo iem standartiem un citi...

Page 3: ...un 12 10 4 Starting up the outdoor unit 12 11 Disposal 12 11 1 Overview Disposal 12 11 2 To pump down 12 11 3 To start and stop forced cooling 13 11 3 1 To start and stop forced cooling using the indo...

Page 4: ...NGER RISK OF ELECTROCUTION WARNING ALWAYS use multicore cable for power supply cables WARNING All wiring MUST be performed by an authorised electrician and MUST comply with the applicable legislation...

Page 5: ...r intrinsically safe Prior to and during work the area MUST be checked with an appropriate refrigerant detector capable of detecting R32 refrigerant to ensure a work environment free of refrigerant WA...

Page 6: ...ed to wind It is recommended to install the outdoor unit with the air inlet facing the wall and NOT directly exposed to the wind b a b c a Baffle plate b Prevailing wind direction c Air outlet 4 1 2 A...

Page 7: ...lable options contact your dealer 1 Use a drain plug for drainage 2 Use a 16 mm hose field supply b c d a a Drain port b Bottom frame c Drain plug accessory d Hose field supply NOTICE Provide at least...

Page 8: ...Make sure the outdoor and indoor unit are mounted Typical workflow Connecting the refrigerant piping involves Connecting the refrigerant piping to the indoor unit Connecting the refrigerant piping to...

Page 9: ...e charging additional refrigerant make sure the outdoor unit s external refrigerant piping is checked leak test vacuum drying INFORMATION Depending on the units and or the installation conditions it m...

Page 10: ...um drying 1 Connect the refrigerant cylinder to the service port 2 Charge the additional refrigerant amount 3 Open the gas stop valve 6 6 To fix the fluorinated greenhouse gases label 1 Fill in the la...

Page 11: ...or unit installation 1 Insulate and fix the refrigerant piping and cables as follows g b a f e c d a Gas pipe b Gas pipe insulation c Interconnection cable d Field wiring if applicable e Liquid pipe f...

Page 12: ...turned OFF INFORMATION Even if the unit is turned OFF it consumes electricity When the power turns back on after a power break the previously selected mode will be resumed 10 4 Starting up the outdoor...

Page 13: ...nt on the indoor unit Method 2 Using the indoor unit user interface 11 3 1 To start and stop forced cooling using the indoor unit ON OFF switch 1 Press the ON OFF switch for at least 5 seconds Result...

Page 14: ...HN HR MR _A MR _B S U V W X A K R_ NE Connection connector D V D Diode DB Diode bridge DS DIP switch E H Heater FU F U for characteristics refer to PCB inside your unit Fuse FG Connector frame ground...

Page 15: ...0253 6E 2022 04 Symbol Meaning V R Diode bridge Insulated gate bipolar transistor IGBT power module WRC Wireless remote controller X Terminal X M Terminal strip block Y E Electronic expansion valve co...

Page 16: ...f c a b d j l k g3 i e RXP20M RXP25M RXP35M ARXP20M ARXP25M ARXP35M h a Liquid field piping h Heat exchanger thermistor b Gas field piping i 4 way valve ON heating c Liquid stop valve j Muffler d Gas...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P650253 6E 2022 04 Copyright 20...

Reviews: