![background image](http://html1.mh-extra.com/html/daikin/rxn25kev1b/rxn25kev1b_service-manual_2459929008.webp)
Removal of Electrical Box / PCB
Si001161
6
Removal Procedure
3. Removal of Electrical Box / PCB
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. Remove the PCB.
Preparation
Remove the panels
according to the “Removal
of Outer Panels”.
Some models have another
wiring for outdoor power-
receiving system.
1
Remove the screws
and release the
connecting wire.
2
Remove the 3 screws
and remove the wire
clamp.
3
4
Disconnect the
connector for the fan
motor [S70].
Release the fan motor
lead wire from the hook.
[S70]: fan motor
5
Release the fan motor
lead wire from the 3
hooks.
(R17481)
Connecting wire
(R15875)
Wire
clamp
[S70]
Hook
Fan motor
lead wire
(R14491)
(R14492)