Specifications
TECHNICAL SPECIFICATIONS
OUTDOOR UNITS
RXH20CVMB
RXH25CVMB
RXH35CVMB
DIMENSIONS
Unit
H
mm
560
W
mm
695
D
mm
265
WEIGHT
kg
31
COLOUR
Unit
Ivory white
SOUND LEVEL
Sound pressure (1) (Cooling)
high/low
dB(A)
46/*
46/*
48/*
Sound pressure (1) (Heating)
high/low
dB(A)
47/*
47/*
48/*
Sound power (2) (Cooling)
high
dB(A)
61
61
63
Sound power (2) (Heating)
high
dB(A)
62
62
63
FAN
Air flow rate (Cooling)
high/low
rpm
29/*
29/*
27.5/*
Air flow rate (Heating)
high/low
rpm
25.5/*
25.5/*
23.5/*
Speed (Cooling)
high
rpm
720
720
710
Speed (Heating)
high
rpm
690
690
690
Model
Propeller fan
Motor output
W
25
HEAT EXCHANGER
Type
Colgate fin,
J
8 grooved tube
Rows x stages x fin pitch
mm
1 x 24 x 1.49
2 x 24 x 1.41
REFRIGERANT CIRCUIT
Refrigerant type
R-410A
Refrigerant charge
kg
0.79
0.79
1.01
Maximum allowable distance between indoor and
outdoor
m
15
15
15
Maximum allowable level difference
15
15
15
Refrigerant control
Motor operated expansion valve
COMPRESSOR
Type
Hermetically sealed swing type
Model
1YC23NXD#A
Motor output
600
Oil type
FVC50K
Oil charge volume
!
0.375
PIPING CONNECTIONS
liquid
mm
φ
6.4
gas
mm
φ
9.5
drain
mm
φ
18.0
INSULATION MATERIAL
Heat insulation
Both liquid and gas pipes
* This information was not available at the time of publication.
ELECTRICAL SPECIFICATIONS
OUTDOOR UNITS
RXH20CVMB
RXH25CVMB
RXH35CVMB
CURRENT
Nominal running current
cooling/heating A
3.12/3.82
3.52/4.22
4.72/4.72
Max. running current
cooling/heating A
Please refer to electrical data
Starting current
cooling/heating A
4.0
4.4
4.9
OUTDOOR UNITS
RXH20CVMB
RXH25CVMB
RXH35CVMB
POWER SUPPLY
VM
NOMINAL DISTRIBUTION
SYSTEM VOLTAGE
Phase
1
∼
Frequency
Hz
50
Voltage
V
230
3D044446
3D044447
3D044448
NOTES
1
The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and
acoustic environment. For measuring conditions: please refer to item 8 of this chapter.
2
The sound power level is an absolute value indicating the ’’power’’ which a sound source generates.
•
Pair Application, Inverter Controlled Unit
•
R-410A
•
RXH20-25-35CVMB
1
2
3
•
Split - Sky Air
•