Outdoor Unit
SiBE041401E
13
Printed Circuit Board Connector Wiring Diagram
2.2
50 Class
Main PCB (PCB2)
Caution
Replace the PCB if you accidentally cut the jumpers other than J8.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of
them.
1) S10
Connector for S11 on filter PCB
2) S12
Connector for HL4, HN4 on filter PCB
3) S20
Connector for electronic expansion valve coil
4) S40
Connector for overload protector
5) S50
Connector for magnetic relay
6) S70
Connector for fan motor
7) S80
Connector for four way valve coil
8) S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
9) HL3, HN3
Connector for HL2, HN2 on filter PCB
10) U, V, W
Terminal for compressor
11) FU2
Fuse (3.15 A, 250 V)
12) LED A
LED for service monitor (green)
13) V1
Varistor
14) J8
Jumper for improvement of defrost performance
∗
Refer to page 109 for detail.
S80
S10
2P358716-1
S70
S20
S40
S90
FU2
S50
LED A
J8
U, V, W
HN3
HL3
S12
V1