13 Technical data
Installer reference guide
25
RXF50+60B2_RXF71A2_RXP50~71L2_(A)RXM42~71N2_RXJ50N2_
RXA42+50B2
R32 split series
4P513661-6B – 2018.05
13.2
Piping diagram
13.2.1
Piping diagram: Outdoor unit
Applicable for: RXP50L, RXF50B
M
HPS
High pressure switch
Automatic reset
Heat exchanger
·7.0· CuT
·7.0· CuT
·7.0· CuT
·7.0· CuT
·12.7· CuT
·12.7· CuT
·12.7· CuT
·12.7· CuT
·12.7· CuT
·12
.7
· C
uT
·9.5· CuT
·6.4· CuT
·9
.5
· C
uT
·6.4· CuT
·6
.4
· C
uT
·6.4· CuT
·6.4· CuT
·4.0· CuT
·4.0· CuT
·9
.5
· C
uT
·12
.7
· C
uT
·12
.7
· C
uT
4-way valve
ON: heating
Propeller fan
Discharge pipe thermistor
Muffler
Muffler
Compressor
Accumulator
Muffler
Muffler
Muffler
Gas stop valve
Liquid stop valve
Field piping
Field piping
Liquid receiver
Filter
Electronic expansion valve
Muffler with filter
Capillary tube ·1·
Capillary tube ·2·
Heat exchanger thermistor
Outdoor temperature
Thermistor
Refrigerant flow
Cooling
Heating
PED categories of equipment
– High pressure switch: category IV; Compressor: category II; Other equipment: art. 4§3.
Applicable for: RXP60L, RXP71L, RXF60B, RXF71A
M
HPS
High pressure switch
Automatic reset
Heat exchanger
·7.0· CuT
·7.0· CuT
·7.0· CuT
·7.0· CuT
·7.0· CuT
·7.0· CuT
·12.7· CuT
·12.7· CuT
·12.7· CuT
·12.7· CuT
·12.7· CuT
·12
.7
· C
uT
·9.5· CuT
·6.4· CuT
·9
.5
· C
uT
·6.4· CuT
·6
.4
· C
uT
·6.4· CuT
·6.4· CuT
·4.0· CuT
·4.0· CuT
·4.0· CuT
·9
.5
· C
uT
·12
.7
· C
uT
·12
.7
· C
uT
·6
.4
· C
uT
4-way valve
ON: heating
Propeller fan
Discharge pipe thermistor
Muffler
Muffler
Compressor
Accumulator
Muffler
Muffler
Muffler
Gas stop valve
Liquid stop valve
Field piping
Field piping
Liquid receiver
Filter
Electronic expansion valve
Muffler with filter
Capillary tube ·1·
Capillary tube ·2·
Capillary tube ·3·
Heat exchanger thermistor
Outdoor temperature
Thermistor
Refrigerant flow
Cooling
Heating
PED categories of equipment
– High pressure switch: category IV; Compressor: category II; Other equipment: art. 4§3.