air conditioner

Operation

manual

1

English

CONTENTS

1. SAFETY PRECAUTIONS ............................... 1

2. SPECIFICATIONS .......................................... 4

3. WHAT TO DO BEFORE OPERATION............ 4

4. REMOTE CONTROLLER AND COOL/HEAT

SELECTOR: NAME AND FUNCTION OF

EACH SWITCH AND DISPLAY  ..................... 4

5. OPERATION RANGE ..................................... 5

6. OPERATION PROCEDURE ........................... 5

7. OPTIMUM OPERATION ................................. 8

8. SEASONAL MAINTENANCE ......................... 9

9. FOLLOWING SYMPTOMS ARE NOT AIR

CONDITIONER TROUBLES .......................... 9

10. TROUBLE SHOOTING................................. 11

Important information regarding the refrigerant 
used

This product contains fluorinated greenhouse gases 
covered by the Kyoto Protocol.

(1)

 GWP = global warming potential

Periodical inspections for refrigerant leaks may be 
required depending on European or local legisla-
tion.
Please contact your local dealer for more informa-
tion.

1. SAFETY PRECAUTIONS

To gain full advantage of the air conditioner’s func-
tions and to avoid malfunction due to mishandling, 
we recommend that you read this instruction manual 
carefully before use.
This air conditioner is classified under “appliances 
not accessible to the general public”.

The precautions described herein are classi-
fied as WARNING and CAUTION. They both 
contain important information regarding 
safety. Be sure to observe all precautions 
without fail. 

WARNING

....... Failure to follow these instruc-

tions properly may result in per-
sonal injury or loss of life.

CAUTION

........ Failure to observe these 

instructions properly may result 
in property damage or personal 
injury, which may be serious 
depending on the circum-
stances.

After reading, keep this manual in a conve-
nient place so that you can refer to it whenever 
necessary. If the equipment is transferred to a 
new user, be sure also to hand over the man-
ual. 

WARNING

Be aware that prolonged, direct exposure to 
cool or warm air from the air conditioner, or to 
air that is too cool or too warm can be harmful 
to your physical condition and health. 
When the air conditioner is malfunctioning 
(giving off a burning odour, etc.) turn off power 
to the unit and contact your local dealer.

Continued operation under such circumstances 
may result in a failure, electric shocks or fire haz-
ards.

Consult your local dealer about installation 
work. 

Doing the work yourself may result in water leak-
age, electric shocks or fire hazards.

Consult your local dealer regarding modifi-
cation, repair and maintenance of the air con-
ditioner.

Improper workmanship may result in water leak-
age, electric shocks or fire hazards.

Do not place objects, including rods, your fin-
gers, etc., in the air inlet or outlet. 

Injury may result due to contact with the air con-
ditioner’s highspeed fan blades.

Never touch the air outlet or the horizontal 
blades while the swing flap is in operation.

Fingers may become caught or the unit may break 
down.

Beware of fire in case of refrigerant leakage.

If the air conditioner is not operating correctly, 
i.e. not generating cool or warm air, refrigerant 
leakage could be the cause. 
Consult your dealer for assistance. 
The refrigerant within the air conditioner is safe 
and normally does not leak. 
However, in the event of a leakage, contact with 
a naked burner, heater or cooker may result in 
generation of noxious gas. 
Do not longer use the air conditioner until a qual-
ified service person confirms that the leakage 
has been repaired.

Refrigerant type

R410A

GWP

(1)

 value

1975

01_EN_3P226891-12Q.fm  Page 1  Saturday, November 27, 2010  2:08 PM

Summary of Contents for RQYQ8PY1B

Page 1: ...RQYQ18PY1B RQYQ20PY1B RQYQ22PY1B RQYQ24PY1B RQYQ26PY1B RQYQ28PY1B RQYQ30PY1B RQYQ32PY1B RQYQ34PY1B RQYQ36PY1B RQYQ38PY1B RQYQ40PY1B RQYQ42PY1B RQYQ44PY1B RQYQ46PY1B RQYQ48PY1B English Deutsch Fran ais...

Page 2: ...00_CV_3P226891 12Q fm Page 2 Saturday November 27 2010 2 07 PM...

Page 3: ...entoenunlugarseguro Unavezquerecibalatarjetadegarant adelconcesionario gu rdelaen unlugarseguro Grazieperavere acquistato questo condizionatore d ariaDaikin Prima di utilizzarequest ultimo leggereatte...

Page 4: ...2 1 4 3 5 6 7 1 7 3 7 2 00_CV_3P226891 12Q fm Page 4 Saturday November 27 2010 2 07 PM...

Page 5: ...8 9 10 11 12 13 14 00_CV_3P226891 12Q fm Page 5 Saturday November 27 2010 2 07 PM...

Page 6: ...00_CV_3P226891 12Q fm Page 6 Saturday November 27 2010 2 07 PM...

Page 7: ...e circum stances After reading keep this manual in a conve nient place so that you can refer to it whenever necessary If the equipment is transferred to a new user be sure also to hand over the man ua...

Page 8: ...or in places with flammable gas corrosive gas or metal dust Using the product in such places may cause fire or product failures Do not use flammable materials e g hairspray or insecticide near the pr...

Page 9: ...y do not play with the unit or its remote con troller Accidental operation by a child may result in impairment of bodily functions and harm health Do not let children play on or around the out door un...

Page 10: ...ime of the system start or stop 9 Display inspection test operation When the inspection test operation button is pressed the display shows the mode in which the system actually is 10 Display under cen...

Page 11: ...nd humidity ranges for safe and effective operation NOTE To avoid condensation and water dripping out the unit If the temperature or the humidity is beyond these conditions safety devices may work and...

Page 12: ...an in cooling operation We recommend starting the operation which was used before using timer operation The following operation is performed in order to prevent the heating capacity from dropping or c...

Page 13: ...wings as shown right and the air flow direction continuously varies Automatic swing setting Press the air flow direction adjust but ton to select the air direction of your choice The air flow flap dis...

Page 14: ...changeover under control of all slave remote controllers connected to the same outdoor unit flashes Press the operation mode selector button of the controller that you wish to designate as the master...

Page 15: ...aracters in the remote controller display appear To protect the unit turn the power on at least 6 hours before operating it This makes operation smoother 8 2 AT THE END OF THE SEASON On a clear day us...

Page 16: ...tion requires a qualified service person Immediately after the cooling operation stops and if the room temperature and humidity are low This is because warm refrigerant gas flows back into the indoor...

Page 17: ...ns occur take the measures shown below and contact your Daikin dealer WARNING Stop operation and shut off the power if any thing unusual occurs burning smells etc Leaving the unit running under such c...

Page 18: ...ove oil gas cooker etc it will cause toxic gas to be generated When a refrigerant leakage failure has been repaired confirm a service person that the leak age point has been corrected surely before re...

Page 19: ...ong as possible Use for appropriate maintenance design budgeting maintenance and inspection fees etc Contact your dealer for details Note Breakage due to taking apart or cleaning inside by anyone othe...

Page 20: ...3P226891 12Q EM10A039 1012 HT 00_CV_3P226891 12Q fm Page 7 Saturday November 27 2010 2 07 PM...

Reviews: