3 Manual operation
3.1 Structure and Components of Solaris
system
Fig. 3-1
Standard design of a ROTEX Solaris solar system (ROTEX recommends a double-sided connection)
1
Cold water connection line
2
Domestic water (hot) distribution line
3
Stainless steel corrugated heat exchanger for domestic water
(hot)
4a
Stainless steel corrugated heat exchanger for storage tank charg-
ing
4a
Stainless steel corrugated heat exchanger for storage tank charg-
ing and heating support
5
Submersion sleeve for storage, return temperature sensors
6
Fill level display
7
Filling and draining hose (
KFE BA,
16 52 15 accessory
)
8
Solaris R4 regulator
9
Solar return line (at the bottom on the solar panel)
10
Solar panel array
11
Solar flow line (at the top on the solar panel)
12
Thermal mixing valve (scalding protection, provided by customer)
13
Convection brake (accessory)
14 Solar flow layering pipe
15
Corrugated stainless steel heat exchanger for heating support
16
Thermal insulation sleeve for corrugated stainless steel heat ex-
changer for heating support
17
Solar return connection
18
Safety overflow connection
A
Zone with water for domestic use
B
Solar zone
FLS Solaris FlowSensor (flow measuring)
P
S
Solaris operating pump
RPS4
Regulation and pump unit
t
DHW
Storage temperature sensor
T
K
Solaris Solar panel temperature sensor
T
R
Solaris Return flow temperature sensor
T
S
Solaris Storage tank temperature sensor
T
V
Solaris Inflow temperature sensor
GCU compact
Gas Combi Unit
HPSU compact
Solar tank with integrated interior heat pump unit
SCS/HYC
Energy store Sanicube Solaris / HybridCube
Tab. 3-1 Legend for fig. 3-1