5 Configuration
Installation manual
16
RHYHBH RHYHBH/X08AAV3
ROTEX HPU hybrid heat pump module
4P353065-1 – 2013.05
Quick heat up function
#
Code
Description
N/A
[C-0A]
Indoor quick heat up function:
▪
0: OFF.
▪
1 (default): On.
Only applicable in case of room
thermostat control. The function will
start up the gas boiler when the actual
room temperature is 3°C lower than the
desired room temperature. The large
boiler capacity can quickly boost up the
room temperature to the desired
temperature. This can be useful after
long periods of absence or after a
breakdown of the system.
Domestic hot water control
Only applicable in case an optional domestic hot water tank is
installed.
#
Code
Description
[A.4.1]
[6-0D]
Domestic hot water Type:
▪
0 (Reheat only): Only reheat operation
is allowed.
▪
1 ( sched.): Same as 2, but
between the scheduled heatup cycles,
reheat operation is allowed.
▪
2 (Scheduled only): The domestic hot
water tank can ONLY be heated
according to a schedule.
[A.4.3.1]
N/A
How is the tank temperature to be
displayed on the user interface?
▪
As temperature.
▪
As graphic: The temperature has to be
displayed as available hot water for
x persons. If you choose this, you also
have to configure which number
equals which temperature under
[A.4.3.2.1]~[A.4.3.2.6]:
[A.4.5]
[6-0E]
The maximum temperature that users
can select for the domestic hot water.
You can use this setting to limit the
temperature at the hot water taps.
Contact/helpdesk number
#
Code
Description
[6.3.2]
N/A
Number that users can call in case of
problems.