5 Configuration
Installation manual
11
RHYHBH RHYHBH/X08AAV3
ROTEX HPU hybrid heat pump module
4P353065-1 – 2013.05
4.5.10
To connect the power consumption digital
inputs
1
Connect the power consumption digital inputs cable to the
appropriate terminals as shown in the illustration below.
X2M
X1M
A4P
A8P
X5M
S6S
S7S
S8S
S9S
a
a
Installation of EKRP1AHTA is required.
2
Fix the cable with cable ties to the cable tie mountings.
4.6
Finishing the indoor unit
installation
4.6.1
To close the indoor unit
1
Close the switch box.
2
Mount the side plate to the unit.
NOTICE
When closing the indoor unit cover, make sure that the
tightening torque does NOT exceed 4.1 N•m.
Before doing the configuration of the heat pump module, the gas
boiler MUST be installed correctly.
5
Configuration
5.1
Indoor unit
5.1.1
Overview: Configuration
If you do NOT configure the system correctly, it might NOT work as
expected. You can configure the system with the user interface.
When you turn ON the user interface for the first time (via the indoor
unit), a quick wizard starts to help you configure the system. If
necessary, you can also make changes to the configuration
afterwards.
NOTICE
The explanation about the configuration in this chapter
gives you ONLY basic explanations. For more detailed
explanation and background information, see the installer
reference guide.
The configuration influences the following:
▪
The calculations of the software
▪
What you can see on and do with the user interface
Legend for the settings tables:
▪
#
: Breadcrumb in the menu structure
▪
Code
: Code in the overview settings
When the installer settings are changed, the system will request to
confirm. When confirmation is complete, the screen will shortly turn
OFF and "busy" will be displayed for several seconds.
The most commonly used installation settings are accessible
through the menu structure. Their location is mentioned by the
breadcrumb indication (#). Additionally, all installer settings can also
be found in
"5.1.3 Menu structure: Overview installer settings" on
page 17
.
For access to the setting codes, see
"To access the installer
settings" on page 12
.
Not all settings are accessible through the menu structure. Some are
only accessible through their code. Then in the table explained
below, the bread crumb is set as N/A (not applicable).
To connect the PC cable to the switch box
Prerequisite:
The EKPCCAB* kit is required.
1
Connect the cable with USB connection to your PC.
2
Connect the plug of the cable to X10A on A1P of the switch box
of the indoor unit.
3
Pay special attention to the position of the plug!
2
3
4
5
H JST