Daikin RoCon+ HP
Daikin controller RoCon+ HP1
008.1447899_00 – 09/2019 – EN
7
Parameter settings
7.1
Explanation of the parameter
tables
The parameter tables listed in
contain com-
pact information on all parameters that are available in the respect-
ive menus and submenus of the controller (1st menu level, 2nd
menu level).
In addition to the parameter designations, the tables contain informa-
tion on setting ranges, factory settings, setting options or adjustment
steps and brief explanations of the function.
In addition, they provide an explanation of the access rights for oper-
ation of the controller. The following abbreviations are used for cor-
responding labelling:
BE
Access right for the operator
HF
Access right with technician code
If different entries are made in the BE and HF columns, the
technician must be logged in before selecting the parameter
level in order to obtain the status entered in the HF column
(see
Status:
N
Not visible
E
Visible and configurable
S
Visible
INFORMATION
Changing some parameters requires a restart of the
device. This takes a few minutes. No further settings can
be made during this time. The restart can be delayed by
5 minutes in response to the prompt "Restart required. Per-
form now?" by selecting "later".
Parameters that require a restart are marked with (*) in the
following tables
7.2
Operating mode
[→ Main menu → Operating mode]
Parameters
Setting range
Min / Max
Description
Factory
setting
Incre-
ment
Access
BE
HF
Standby
In this operating mode all internal functions are switched off. Frost protec-
tion remains active and a blocking protection for the pump is guaranteed.
All controllers integrated in the RoCon system via the CAN bus are primar-
ily also switched to the operating mode if this setting is selected.
Outputs are not always completely free of voltage.
-
E
E
Reduce
The internal HC continuously regulates to the required reduced feed tem-
perature according to the [Heating curve] or [Feed temperature, reducing
mode] parameters or to the room temperature [Reduce room temperature]
if the room thermostat is connected. Domestic hot water preparation is car-
ried out according to [Hot water auto. 1].
-
E
E
Heating
The internal HC continuously regulates to the required feed temperature
according to the [Heating curve] or [Feed temperature, heating mode]
parameters or to the room temperature [Room temperature target 1] if the
room thermostat is connected. Domestic hot water preparation is carried
out according to [Hot water auto. 1].
-
E
E
Summer
The internal HC is switched off. Frost protection remains active and a
blocking protection for the pump is guaranteed. Domestic hot water prepar-
ation is carried out according to [Hot water auto. 1].
All controllers integrated in the RoCon system via the CAN bus are primar-
ily also switched to the operating mode if this setting is selected.
-
E
E
Automatic 1
The internal heating circuits are controlled according to the set [Heating cir-
cuit auto. 1] time program with the respective room target temperatures.
Domestic hot water preparation is carried out according to [Hot water auto.
1].
-
E
E
Automatic 2
The internal heating circuits are controlled according to the set [Heating cir-
cuit auto. 2] time program with the respective room target temperatures.
Domestic hot water preparation is carried out according to [Hot water auto.
2].
-
E
E
Cooling
The internal heating circuit continuously regulates to the required feed tem-
perature according to the parameters in the menu [→ Main menu → Con-
figuration → Cooling] or to the [Room temperature target 1] room temperat-
ure if the room thermostat is connected. Domestic hot water preparation is
carried out according to [Hot water auto. 1]. Frost protection remains active
and a blocking protection for the pump is guaranteed.
-
E
E
Tab. 7-1
Parameter in the "Operating mode" menu
Summary of Contents for RoCon+ HP Series
Page 116: ...Betriebsanleitung 116 Daikin RoCon HP Daikin Regelung RoCon HP1 008 1447899_00 09 2019 DE ...
Page 236: ...Gebruiksaanwijzing 236 Daikin RoCon HP Daikin regeling RoCon HP1 008 1447899_00 09 2019 NL ...
Page 351: ...Driftsvejledning 351 Daikin RoCon HP Daikin regulering RoCon HP1 008 1447899_00 09 2019 DA ...
Page 406: ...Instruktionsbok 406 Daikin RoCon HP Daikin reglerenhet RoCon HP1 008 1447899_00 09 2019 SV ...
Page 460: ...Brukerveiledning 460 Daikin RoCon HP Daikin Regulering RoCon HP1 008 1447899_00 09 2019 NO ...
Page 516: ...008 1447899_00 09 2019 EN DE FR NL IT DA SV NO FI Copyright Daikin ...