Electrical Components / Partition Plate
Si011414E
6
Removal Procedure
3. Electrical Components / Partition Plate
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
2
Remove the screw of
the wire fixture.
Unfasten the hook and
remove the wire fixture.
3
Remove the 2 screws
on the terminal board
and disconnect the
connecting wire.
4
Remove the 5 screws
and remove the right
side panel.
Hook
Wire fixture
(R21353)
Connecting wire
Terminal board
Screw
(R21354)
Right side panel
(R21355)