![background image](http://html1.mh-extra.com/html/daikin/rn25hv1a/rn25hv1a_service-manual_2459870007.webp)
Si01-980
Removal of Panels / Fan Motor
Removal Procedure
5
2
Remove the outdoor
fan.
Align the
mark of the
outdoor fan with the D-cut
section of the motor shaft
when reassembling.
3
Disconnect the
connector for the fan
motor.
4
Release the fan motor
lead wire from the fixing
hook.
Put the lead wire through the
back of the motor when
reassembling. (so as not to
be entangled with the
outdoor fan)
Step
Procedure
Points
D-cut
(R11422)
(R11416)
Fan motor
lead wire
(R11423)
(R3249)
Lead wire
Outdoor fan