![background image](http://html1.mh-extra.com/html/daikin/rn25hv1a/rn25hv1a_service-manual_2459870011.webp)
Si01-980
Removal of Electrical Components (Pattern 1)
Removal Procedure
9
2. Removal of Electrical Components (Pattern 1)
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Remove the electrical
component ASSY.
Preparation
Remove the top panel.
Disconnect the connector for
the fan motor.
1
Lift and remove the
sound blanket (top).
2
Remove the nut and
remove the terminal
cover.
3
Disconnect the
compressor lead wires
with a flat screwdriver.
S(W) : Yellow
C(U) : Blue
R(V) : Red
4
Lift and remove the
electrical component
ASSY.
(R11439)
Sound blanket
(top)
(R11440)
Terminal
cover
(R11441)
Compressor
lead wire
S(W)
R(V)
(R6761)
C(U)
Electrical component ASSY
(R11442)