Si001355E
Electrical Box / PCB
Removal Procedure
9
2
Remove the 7 screws
of the PCB.
3
Remove the earth /
ground screw (upper).
4
Cut the clamp of the
relay connector
harness.
5
Remove the PCB.
Step
Procedure
Points
(R19444)
PCB
(R19445)
Earth / ground
wire (upper)
(R19439)
Clamp
(R19446)