![Daikin RKV50NRV16 Service Manual Download Page 5](http://html.mh-extra.com/html/daikin/rkv50nrv16/rkv50nrv16_service-manual_2459867005.webp)
Si001355E
Outdoor Fan / Fan Motor
Removal Procedure
3
2. Outdoor Fan / Fan Motor
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Disconnect the
connector [S70].
[S70]: fan motor
2
Release the fan
motor lead wire from
the groove of the
partition plate and
the 4 hooks on the
electrical box.
3
Remove the nut and
remove the outdoor fan.
Nut size: M6
When reassembling, align
the
mark of the outdoor
fan with the D-cut section of
the motor shaft.
(R19430)
[S70]
Hook
(R19360)
Outdoor fan
(R19431)
10 mm
(0.39 inch)
(R18954)