Electrical Box
Si001269EA
6
Removal Procedure
3. Electrical Box
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Remove the 2 screws
of the shield plate.
2
Slide the shield plate
upward to unfasten the
hook on the bottom left,
and then remove the
shield plate.
3
Remove all the screws
of the terminal boards
and of the earth /
ground wires.
Disconnect the power
supply wire and the
connecting wire.
4
Remove the 2 screws
and detach the earth /
ground wires.
(R17060)
Shield
plate
(R17021)
Hook
(R20181)
Power supply wire
Earth / ground
wire
Connecting wire
(R20182)
Earth / ground
wire