![background image](http://html1.mh-extra.com/html/daikin/rks50fvmv/rks50fvmv_removal-procedure_4701540010.webp)
Electrical Box
Si001269EA
8
Removal Procedure
8
Disconnect the
connectors and pull out
each clamp of the front
side.
[S20]: electronic expansion
valve coil
[S40]: overload protector
[S80]: four way valve coil
[S90]: thermistors
When reassembling, insert
each clamp into the hole as
below.
9
Disconnect the relay
connector for the
compressor.
10
Release the clamp.
11
Detach the clamp and
release the thermistor
lead wires from the
hook.
12
Remove the screw.
Step
Procedure
Points
(R17137)
[S40] [S20]
[S90]
[S80]
Thermistor ASSY harness
Electronic
expansion
valve coil
harness
Fan
motor
lead wire
(R17138)
(R17139)
(R17140)
Thermistor lead wire
Hook
Fixing position for the
thermistor harness
When reassembling, insert
the clamp into the small
hole.
(R12316)