![background image](http://html1.mh-extra.com/html/daikin/rks50fvmv/rks50fvmv_removal-procedure_4701540012.webp)
PCBs
Si001269EA
10
Removal Procedure
4. PCBs
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Disconnect the
connectors [S52]
[S102] from the service
monitor PCB.
[S52]: control PCB
[S102]: control PCB
2
Detach the 4 clamps
with pliers and remove
the service monitor
PCB.
3
4
Remove the screws of
the terminal board and
the earth / ground wire.
Unfasten the hook on
the right.
5
6
Open the terminal
board.
Disconnect the
harnesses.
1: Black
2: White
3: Red
L1: Black
L2: Brown
N1: White
N2: Blue
(R16707)
Service monitor PCB
[S52]
[S102]
Clamp
(R16708)
(R20183)
Terminal board
Hook
Earth / ground
wire
L2
N2
1 2 3
L1
N1
(R17562)