PCBs
Si001163EA
16
Removal Procedure
4. PCBs
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1. Remove the main PCB.
[S12]: filter PCB
1
Disconnect the
connector [S12] and
pull out the clamp.
2
Disconnect the
connector [S10].
[S10]: filter PCB
3
Pull out the clamp.
When reassembling, make
sure the compressor
harness clamp is securely
fastened.
(R16959)
[S12]
Main PCB
(R16808)
[S10]
(R16775)
(R24309)
Compressor harness
(red, blue, yellow)
Top view