23
10
Release the thermistor
harness from the hook
at the bottom of
electrical box.
11
Pull out the clamp of the
thermistor harness from
the hole of the electrical
box.
12
Slide the electrical box
leftward to unfasten the
hook on the right side of
the box.
13
Lift up the electrical box
and remove it.
Step
Procedure
Points
Fixing position for the
thermistor harness
Hook
(R16647)
When reassembling, insert
the clamp into the small hole.
Electrical box
Hook
(R16643)