2
Specifications
TECHNICAL SPECIFICATIONS
OUTDOOR UNITS
RKS25BVMB
RKS35BVMB
RKS50BVMB
RKS60BVMB
RKS71BVMB
DIMENSIONS
Unit
H
mm
560
735
W
mm
695
825
D
mm
265
300
WEIGHT
kg
37
49
53
55
COLOUR
Unit
Ivory white
SOUND LEVEL
Sound pressure (1) (Cooling) High/Low
dBA
46/43
47/44
47/*
49/*
52/*
Sound power (2) (Cooling)
High
dBA
59
60
63
64
66
FAN
Air flow rate (Cooling)
High/Low
m
3
/min
25.3/17.0
25.3/17.0
47.7/44.1
47.6/44.1
51.5/41.5
Speed (Cooling)
high
rpm
670
670
700
730
790
low
rpm
450
450
650
680
650
Model
Propeller fan
Motor output
W
19
53
HEAT EXCHANGER
Type
Waffle fin,
J
8 Hi-XA tube
Rows x stages x fin pitch
mm
2 x 24 x 1.5
1 x 32 x 1.6
2 x 32 x 1.8
REFRIGERANT CIRCUIT
Refrigerant type
R-410A
Refrigerant charge
kg
0.96
1.06
1.20
1.70
1.70
Maximum allowable distance between indoor
and outdoor
m
25
30
Maximum allowable level difference
m
15
20
Refrigerant control
Motor operated expansion valve
-
COMPRESSOR
Type
Hermetically sealed swing type
Model
1YC23GXD#A
2YC32HXD
2YC45BXD
Motor output
600
600
1,500
1,500
1,900
Oil type
FVC50K
Oil charge volume
!
0.40
0.40
0.65
0.65
0.75
PIPING CONNECTIONS
liquid
mm
φ
6.4
gas
mm
φ
9.5
φ
12.7
φ
15.9
drain
mm
φ
18.0
INSULATION MATERIAL
Heat insulation
Both liquid and gas pipes
* This information was not available at the time of publication.
•
Pair Application
•
R-410A
•
RKS25-35-50-60-71BVMB
2
3
•
Split - Sky Air
•
Outdoor Units