Si00-776
Removal of Reactor
Removal Procedure
29
6. Removal of Reactor
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1
Remove the screw.
2
Lift the reactor to
unfasten the hooks, and
remove the reactor.
(R16901)
(R16902)
Hook
Reactor