Removal of Electrical Box
Removal Procedure
17
7
Disconnect the
connector for the
electronic expansion
valve coil [S20].
When reassembling, insert
the clamps of the thermistor
ASSY into the hole as below.
8
Disconnect the
connector for the
thermistors [S90].
9
Disconnect the
connector for the
overload protector (OL)
[S40].
Step
Procedure
Points
(R16893)
[S20]
(R17101)
[S90]
Outdoor temperature
thermistor, outdoor heat
exchanger thermistor
Discharge pipe
thermistor
Thermistor
ASSY
(R17095)
(R17102)
[S40]