background image

 

Although this is a recognized measure for additional 

protection, with the grounding system in North 

America, a dedicated GFCI may not be necessary.

CAUTION

 

Do not use the air conditioner or heat pump for any 

other purposes other than comfort cooling or heating. 

Do not use the unit for cooling precision instruments, 

food, plants, animals or works of art.

 

Do not place items under the indoor unit it could result 

in damage by condensates that may form if the humidity 

is above 80% or if the drain outlet gets blocked.

 

Before cleaning, stop the operation of the unit by 

turning the power off or by pulling the supply cord out 

from its receptacle. Otherwise, an electric shock and 

injury could result.

 

Do not wash the air conditioner or heat pump with 

excessive water. An electric shock or fire could result.

 

Avoid placing the controller in a spot splashed with 

water. Water entering the controller could result in an 

electric shock or damage the internal electronic parts.

 

Do not operate the air conditioner or heat pump when 

using a room fumigation type of insecticide. Failure to 

observe this could result in the chemicals to be 

deposited in the unit and can endanger the health of 

those who are hypersensitive to chemicals.

 

Do not turn off the power immediately after stopping 

operation. Always wait for at least five minutes before 

turning off the power. Otherwise, water leakage could 

result.

 

The appliance is not intended for use by young 

children or infirm persons without supervision.

 

The remote controller should be kept away from 

children so they cannot play with it.

 

Consult with the installation contractor for cleaning.

 

Incorrect cleaning of the inside of the air conditioner 

or heat pump could result in the plastics parts break 

resulting in water leakage or electric shock.

 

Do not touch the air inlet or aluminum fin of the air 

conditioner or heat pump as they can cut and could 

result in injury.

 

Do not place objects in direct proximity of the outdoor 

unit. Do not let leaves and other debris accumulate 

around the unit. Leaves are a hotbed for small animals 

which can enter the unit. Once inside the unit, animals 

result in the unit malfunctioning, and could result in 

smoke or fire when they make contact with electrical 

parts.

NOTE

 

Never press the button of the remote controller with a 

hard, pointed object. The remote controller result in 

damage.

 

Never pull or twist the electric wire of the remote 

controller. It may result in the unit malfunctioning.

 

Do not place appliances that produce open flames in 

places that are exposed to the air flow of the unit or 

under the indoor unit. It may result in incomplete 

combustion or deformation of the unit due to the heat.

 

Do not expose the controller to direct sunlight. The 

LCD display can become discolored and may result in 

fail to display the data.

 

Do not wipe the controller operation panel with 

benzene, thinner, chemical dust cloth, etc. The result 

may be that the panel becomes discolored or the 

coating can peel off. If it is heavily dirty, soak a cloth in 

water-diluted neutral detergent, squeeze it well and 

wipe the panel clean. Then wipe it with another dry 

cloth.

 

Dismantling of the unit, disposal of the refrigerant, oil, 

and additional parts, should be done in accordance 

with the relevant local, state, and national regulations.

 

Operate the air conditioner or heat pump in a 

sufficiently ventilated area and not surrounded by 

obstacles. Do not use the air conditioner or heat pump 

in the following places.

a. Places with a mist of mineral oil, such as cutting oil.

b. Locations such as coastal areas where there is a lot 

of salt in the air.

c. Locations such as hot springs where there is a lot 

of sulfur in the air.

d. Locations such as factories where the power 

voltage varies a lot.

e. In cars, boats, and other vehicles.

f.  Locations such as kitchens where oil may splatter 

or where there is steam in the air.

g. Locations where equipment produces 

electromagnetic waves.

h. Places with an acid or alkaline mist.

i.  Places where fallen leaves can accumulate or where 

weeds can grow.

 

Take snow protection measures. Contact your dealer 

for the details of snow protection measures, such as 

the use of a snow protection hood.

 

Do not attempt to do electrical work or grounding work 

unless you are licensed to do so. Consult with your 

dealer for electrical work and grounding work.

 

Pay Attention to Operating Sound. Be sure to use the 

following places:

a. Places that can sufficiently withstand the weight of 

the air conditioner or heat pump yet can suppress 

the operating sound and vibration.

b. Places where warm air from the air outlet of the 

outdoor unit or the operating sound of the outdoor 

unit does not annoy neighbors.

 

Make sure that there are no obstacles close to the 

outdoor unit. Obstacles close to the outdoor unit may 

drop the performance of the outdoor unit or increase 

the operating sound of the outdoor unit.

 

Consult your dealer if the air conditioner or heat pump 

in operation generates unusual noise.

 

Make sure that the drainpipe is installed properly to 

drain water. If no water is discharged from the 

drainpipe while the air conditioner or heat pump is in 

the cooling mode, the result may be that the drainpipe 

becomes clogged with dust or dirt and water leakage 

from the indoor unit may occur. Stop operating the air 

conditioner or heat pump and contact your dealer.

ii

3P477778-8G English

01_EN_3P477778-8G.indd   2

12/12/2018   3:31:21 PM

Summary of Contents for REYQ72XATJU

Page 1: ...REYQ384XAYDU REYQ408XAYDU REYQ432XAYDU REYQ456XAYDU REYQ72XAYCU REYQ96XAYCU REYQ120XAYCU REYQ144XAYCU REYQ168XAYCU REYQ192XAYCU REYQ216XAYCU REYQ240XAYCU REYQ264XAYCU REYQ288XAYCU REYQ312XAYCU REYQ33...

Page 2: ...eakage electric shock and fire Only use accessories made by Daikin that are specifically designed for use with the equipment and have them installed by a professional Contact your dealer to move and r...

Page 3: ...result in incomplete combustion or deformation of the unit due to the heat Do not expose the controller to direct sunlight The LCD display can become discolored and may result in fail to display the...

Page 4: ...unless you are licensed to do so Consult with your local dealer for electrical work and grounding work Use a dedicated circuit for the air conditioner Pay Attention to Operating Sound Be sure to use...

Page 5: ...REYQ144XAYCU REYQ168XAYCU REYQ192XAYCU REYQ216XAYCU REYQ240XAYCU REYQ264XAYCU REYQ288XAYCU REYQ312XAYCU REYQ336XAYCU REYQ360XAYCU REYQ384XAYCU REYQ408XAYCU REYQ432XAYCU Contents Safety Considerations...

Page 6: ...inal cooling Maximum capacity Btu h 72 000 96 000 120 000 144 000 168 000 Nominal heating Maximum capacity Btu h 81 000 108 000 135 000 162 000 188 000 Dimensions H W D inch mm 66 11 16 1694 48 7 8 12...

Page 7: ...Note The Cool Heat selector cannot connect to the multi Branch Selector unit Operation Range COOLING HEATING Outdoor temperature 23 to 110 FDB 5 to 43 CDB 13 to 60 FWB 25 to 16 CWB Indoor temperature...

Page 8: ...ler For more information see the operation manual that came with the remote controller Operation Procedure Operation procedure varies according to the combination of outdoor unit and remote controller...

Page 9: ...icates the available operating modes of the other indoor units on the system based upon the selected mode of the master indoor unit When the master indoor unit is set to The other indoor units in the...

Page 10: ...t Filter Indicator Air Flow Direction Ventilation Schedule Off Timer Celsius Fahrenheit 1 2 Cool Set to Cool 74F Press buttons to select Reset Filter Indicator on the main menu screen and press Menu O...

Page 11: ...r code and model name or code Precautions for Group Control System or Two Remote Controller Control System This system provides two other control systems beside individual control one remote controlle...

Page 12: ...temperature We recommend starting the operation in advance using schedule operation Seasonal Maintenance Caution Do not touch the air inlets or aluminum fins of the outside or indoor units Touching th...

Page 13: ...utomatically restarts when the noise goes away Cool heat cannot be changed over When the display shows MASTER CONTROLLED It shows that this is a slave remote controller When the Cool Heat selector swi...

Page 14: ...e make this noise A low sound like dripping water is heard while the indoor unit is stopped When the other indoor unit is in operation this noise is heard In order to prevent oil and refrigerant from...

Page 15: ...oblem after checking all the above items contact your local dealer Let them know the symptoms system name and model name 1 If the system does not operate at all Check if there is no power failure Wait...

Page 16: ...ate and installation date Malfunction Inform the staff of the defective details Malfunction code being displayed on the remote controller Name address telephone number Repair after the warranty term i...

Page 17: ...n locations where power fluctuation voltage frequency wave distortion etc is high Cannot be used if it is outside the allowable range 3 When installed and used in locations where bumps and vibrations...

Page 18: ...aler for discarding this unit since it is required by law to collect transport and discard the refrigerant in accordance with chlorofluorocarbon collection and destruction law Where to call For after...

Page 19: ...3P477778 8G EM18A016 1901 HT 00_CV_3P477778 8G indd 2 12 12 2018 3 29 15 PM...