Following Symptoms are not Air Conditioner Troubles

 

„

The system does not operate

 

The air conditioner does not start immediately when restarting or changing the operation mode.

 

If the operation lamp lights, the system is in normal condition. 
To prevent overloading of the compressor motor, the air conditioner starts 5 minutes after it is turned ON again in case it was turned OFF just 
before.

 

If “

 

CENTRAL 

CONTROL

 

” is displayed on the remote controller and pressing the operation button causes the display to blink for a few 

seconds.

 

This indicates that the central device is controlling the unit. 
The blinking display indicates that the remote control cannot be used.

 

The system does not start immediately after the power supply is turned on.

 

Wait 10 minutes until the micro computer is prepared for operation.

 

„

It stops sometimes

 

The remote controller display reads “U4” or “U5” and the unit stops but then restarts after a few minutes.

 

This is because the remote control is intercepted by noise from electrical appliances other than the air conditioner, and this prevents 
communication between the units, causing them to stop. 
Operation automatically restarts when the noise goes away.

 

„

Cool/heat cannot be changed over

 

When the display shows “

 

MASTER 

CONTROLLED

 

”.

 

It shows that this is a slave remote controller.

 

When the Cool/Heat selector switch is installed and the display shows “

 

MASTER 

CONTROLLED

 

”.

 

This is because COOL/HEAT changeover is controlled by the Cool/Heat selector. Ask your local dealer where the Cool/Heat selector is installed.

 

„

Fan operation is possible, but cooling and heating do not work

 

Immediately after the power is turned on.

 

The micro computer is getting ready to operate. Wait 10 minutes.

 

„

The fan speed does not correspond to the setting

 

The fan speed does not change even if the fan speed control button is pressed.

 

During heating operation, when the room temperature reaches the set temperature, the outdoor unit goes off and the indoor unit changes to 
whisper the fan speed. 
This is to prevent cold air blowing directly on occupants of the room. 
The fan speed will not change even if the button is pressed, when another indoor unit is in heating operation.

 

„

The fan direction does not correspond to the setting

 

The fan direction does not correspond to the remote control display.

 

The fan direction does not swing.

 

This is because the unit is being controlled by the micro computer.

9

3P477778-8G English

01_EN_3P477778-8G.indd   9

12/12/2018   3:31:24 PM

Summary of Contents for REYQ72XATJU

Page 1: ...REYQ384XAYDU REYQ408XAYDU REYQ432XAYDU REYQ456XAYDU REYQ72XAYCU REYQ96XAYCU REYQ120XAYCU REYQ144XAYCU REYQ168XAYCU REYQ192XAYCU REYQ216XAYCU REYQ240XAYCU REYQ264XAYCU REYQ288XAYCU REYQ312XAYCU REYQ33...

Page 2: ...eakage electric shock and fire Only use accessories made by Daikin that are specifically designed for use with the equipment and have them installed by a professional Contact your dealer to move and r...

Page 3: ...result in incomplete combustion or deformation of the unit due to the heat Do not expose the controller to direct sunlight The LCD display can become discolored and may result in fail to display the...

Page 4: ...unless you are licensed to do so Consult with your local dealer for electrical work and grounding work Use a dedicated circuit for the air conditioner Pay Attention to Operating Sound Be sure to use...

Page 5: ...REYQ144XAYCU REYQ168XAYCU REYQ192XAYCU REYQ216XAYCU REYQ240XAYCU REYQ264XAYCU REYQ288XAYCU REYQ312XAYCU REYQ336XAYCU REYQ360XAYCU REYQ384XAYCU REYQ408XAYCU REYQ432XAYCU Contents Safety Considerations...

Page 6: ...inal cooling Maximum capacity Btu h 72 000 96 000 120 000 144 000 168 000 Nominal heating Maximum capacity Btu h 81 000 108 000 135 000 162 000 188 000 Dimensions H W D inch mm 66 11 16 1694 48 7 8 12...

Page 7: ...Note The Cool Heat selector cannot connect to the multi Branch Selector unit Operation Range COOLING HEATING Outdoor temperature 23 to 110 FDB 5 to 43 CDB 13 to 60 FWB 25 to 16 CWB Indoor temperature...

Page 8: ...ler For more information see the operation manual that came with the remote controller Operation Procedure Operation procedure varies according to the combination of outdoor unit and remote controller...

Page 9: ...icates the available operating modes of the other indoor units on the system based upon the selected mode of the master indoor unit When the master indoor unit is set to The other indoor units in the...

Page 10: ...t Filter Indicator Air Flow Direction Ventilation Schedule Off Timer Celsius Fahrenheit 1 2 Cool Set to Cool 74F Press buttons to select Reset Filter Indicator on the main menu screen and press Menu O...

Page 11: ...r code and model name or code Precautions for Group Control System or Two Remote Controller Control System This system provides two other control systems beside individual control one remote controlle...

Page 12: ...temperature We recommend starting the operation in advance using schedule operation Seasonal Maintenance Caution Do not touch the air inlets or aluminum fins of the outside or indoor units Touching th...

Page 13: ...utomatically restarts when the noise goes away Cool heat cannot be changed over When the display shows MASTER CONTROLLED It shows that this is a slave remote controller When the Cool Heat selector swi...

Page 14: ...e make this noise A low sound like dripping water is heard while the indoor unit is stopped When the other indoor unit is in operation this noise is heard In order to prevent oil and refrigerant from...

Page 15: ...oblem after checking all the above items contact your local dealer Let them know the symptoms system name and model name 1 If the system does not operate at all Check if there is no power failure Wait...

Page 16: ...ate and installation date Malfunction Inform the staff of the defective details Malfunction code being displayed on the remote controller Name address telephone number Repair after the warranty term i...

Page 17: ...n locations where power fluctuation voltage frequency wave distortion etc is high Cannot be used if it is outside the allowable range 3 When installed and used in locations where bumps and vibrations...

Page 18: ...aler for discarding this unit since it is required by law to collect transport and discard the refrigerant in accordance with chlorofluorocarbon collection and destruction law Where to call For after...

Page 19: ...3P477778 8G EM18A016 1901 HT 00_CV_3P477778 8G indd 2 12 12 2018 3 29 15 PM...

Reviews: