![background image](http://html1.mh-extra.com/html/daikin/re18mv2s/re18mv2s_service-manual_2459791011.webp)
Si011193
Removal of Electrical Components
Removal Procedure
9
2. Remove the electrical
component ASSY.
Fan capacitor (C12R)
Magnetic contactor (K1M)
1
Pull out the 2 terminals
[A1] [B1] from the fan
capacitor (C12R).
2
Pull out the terminal [5]
from the magnetic
contactor (K1M).
3
Release the fan motor
lead wire from the hook.
4
Pull out the terminal [1]
from the magnetic
contactor (K1M).
5
Pull out the 2 terminals
[A1] [B1] from the
compressor capacitor
(C11R).
Magnetic contactor (K1M)
Compressor capacitor
(C11R)
Compressor lead wire
S(W) : yellow
C(U) : blue
R(V) : red
6
Lift and remove the
electrical component
ASSY.
Step
Procedure
Points
to fan motor
(red)
to fan motor
(white)
(R15394)
B1 B2
A1 A2
A2
14
6
4
2
A1
13
5
3
1
to fan motor
(black)
(R15395)
(R15157)
Magnetic contactor
Fan motor lead wire
Fan capacitor
(R15174)
Compressor capacitor
A2
14
6
4
2
A1
13
5
3
1
(R17474)
to compressor (C terminal):
blue
(R17473)
to compressor
(S terminal) :
yellow
to compressor
(R terminal) :
red
B2
A2
B1
A1
S(W)
C(U)
R(V)
(R15376)
(R15175)
Electrical component ASSY