![background image](http://html.mh-extra.com/html/daikin/r60gv1g/r60gv1g_service-manual_2460293010.webp)
Removal of Electrical Components ASSY
Si01-881
8
Removal Procedure
2. Remove the outdoor
temperature thermostat.
Remove the sensor fixing
plate.
1
Detach the outdoor
temperature sensor.
2
Disconnect the
terminals of the outdoor
temperature thermostat
(S1T).
3
Remove the screw and
remove the outdoor
temperature
thermostat.
Step
Procedure
Points
(R12813)
Outdoor
temperature
sensor
(R12814)
(R12815)
Outdoor
temperature
thermostat
(S1T)
(R8335)