• Split Sky Air • Outdoor Units

7

• Outdoor Units • R-410A • RXS-G2V1B

2

Specifications

3

2

Sound Level 
(nominal)

Cooling

Sound Power

dBA

61

61

63

63

62

Sound Pressure 
(Low)

dBA

43

43

44

44

44

Sound Pressure 
(High)

dBA

46

46

48

48

48

Heating

Sound Pressure 
(Low)

dBA

44

44

45

45

45

Sound Pressure 
(High)

dBA

47

47

48

48

48

Refrigerant

Type

R-410A

Charge

kg

0.8

1.0

1.2

1.3

1.7

Refrigerant Oil

Type

FVC50K

Charged Volume

l

0.375

0.375

0.375

0.65

0.65

Piping connections

Liquid (OD)

Diameter (OD)

mm

6.35

6.35

6.35

6.35

6.35

Gas

Diameter (OD)

mm

9.52

9.52

9.52

9.52

12.7

Drain

Diameter (OD)

mm

18

18

18

18

18

Piping Length

Maximum

m

20

20

20

20

30

Additional Refrigerant Charge

kg/m

0.02>10m

Installation height 
difference

Maximum

m

15

15

15

15

20

Heat Insulation

Both liquid and gas pipes

Standard 
Accessories

Item

Installation manual

Quantity

1

1

1

1

1

Item

Drain plug

Quantity

1

Notes

Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19.0°CWB; outdoor 

temperature: 35°CDB, 24°CWB, refr.pip.length: 5m

Nominal heating capacities are based on: indoor temperature: 20°CDB; outdoor temperature: 7°CDB, 

6°CWB, refr.pip.length: 5m

2-3 ELECTRICAL SPECIFICATIONS

RXS20G2V1B

RXS25G2V1B

RXS35G2V1B

RXS42G2V1B

RXS50G2V1B

Power Supply

Name

V1

Phase

1~

Frequency

Hz

50

50

50

50

50

Voltage

V

220-230-240

Current

Nominal running 
current (RLA)

Cooling (A)

A

2.67-2.55-2.45

3.06-2.93-2.81

4.26-4.08-3.91

6.04-5.78-5.54

6.93-6.63-6.35

Heating (A)

A

3.50-3.35-3.21

4.14-3.96-3.80

4.71-4.50-4.31

7.27-6.96-6.67

7.13-6.82-6.54

Starting current (cooling/heating)

A

3.6

4.3

4.8

7.4

7.3

Wiring connections

For Power Supply

Quantity

3

3

3

3

3

For connection with 
indoor

Quantity

4

4

4

4

4

Remark

(including earth wiring)

2-2 TECHNICAL SPECIFICATIONS

RXS20G2V1B

RXS25G2V1B

RXS35G2V1B

RXS42G2V1B

RXS50G2V1B

Summary of Contents for R-410A

Page 1: ...technical data RXS G2V1B Outdoor units air conditioning systems Split Sky Air EEDEN09 100...

Page 2: ...RXS G2V1B Outdoor units EEDEN08 100 technical data air conditioning systems Split Sky Air...

Page 3: ...l Input 3 Technical Specifications 6 Electrical Specifications 7 3 Electrical data 8 4 Capacity tables 13 Cooling Heating capacity tables 13 5 Dimensional drawing centre of gravity 25 Dimensional draw...

Page 4: ...l i t S k y R X S G 2 V 1 B R 4 1 0 A Outdoor units for pair application Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wal...

Page 5: ...4 040 4 470 5 160 5 590 Power Input Cooling Minimum kW 0 32 0 32 0 35 0 44 0 44 Standard kW 0 47 0 55 0 87 1 22 1 52 Maximum kW 0 91 0 81 1 19 2 23 1 81 Heating Minimum kW 0 31 0 31 0 34 0 40 0 40 St...

Page 6: ...970 Power Input Cooling Minimum kW 0 30 0 30 0 50 Standard kW 0 57 1 02 1 55 Maximum kW 0 92 1 25 2 00 Heating Minimum kW 0 29 0 31 0 50 Standard kW 0 79 1 22 1 60 Maximum kW 1 39 1 88 2 60 For combin...

Page 7: ...onsumption kWh 365 550 900 Indoor Units FCQ35C7VEB FCQ50C7VEB Cooling capacity Standard kW 3 40 5 00 Heating capacity Standard kW 4 20 6 00 Power Input Cooling Standard kW 0 95 1 41 Heating Standard k...

Page 8: ...Rows 1 2 2 2 2 Fin Pitch mm 1 4 1 4 1 4 1 5 1 8 Nr of Stages 24 24 24 24 32 Tube type Hi Xa 7 Hi Xa 7 Hi Xa 7 Hi Xa 8 Hi Xa 8 Fin Type Waffle fin Treatment Anti corrosion treatment PE Fan Type Propel...

Page 9: ...ssories Item Installation manual Quantity 1 1 1 1 1 Item Drain plug Quantity 1 Notes Nominal cooling capacities are based on indoor temperature 27 CDB 19 0 CWB outdoor temperature 35 CDB 24 CWB refr p...

Page 10: ...LA Rated Load Amps A OFM Outdoor Fan Motor IFM Indoor Fan Motor FLA Full Load Amps A W Fan Motor Rated Output W RHz Rated Operated Frequency Hz 3D055008B Representative Unit Combination Power Supply C...

Page 11: ...ased on the larger value of MCA 4 Instead of fuse use circuit breaker 5 For more details concerning conditional connections see http extranet daikineurope com select E Data Books Finally click on the...

Page 12: ...Data Books Finally click on the document title of your choice SYMBOLS MCA Min Circuit Amps A MFA Max Fuse Amps A see note 4 A RHZ Rated Operating Frequency Hz RLA Rated Load Amps A OFM Outdoor Fan Mot...

Page 13: ...based on the larger value of MCA 4 Instead of fuse use circuit breaker 5 For more details concerning conditional connections see http extranet daikineurope com select E Data Books Finally click on the...

Page 14: ...98V 19 75 20 70 6 6 53 0 27 23 0 15 50 230 6 2 SIMBOLS NOTES MCA Min circuit amps A 1 RLA is based on the following conditions Indoor temp 27C DB 19 CWB Outdoor Temp 35 CDB 2 Maximum allowable voltage...

Page 15: ...0 6 10 C TC PI TC PI TC PI TC PI TC PI 15 0 1 82 0 53 2 12 0 56 2 43 0 58 2 79 0 62 3 04 0 64 20 0 1 72 0 55 2 03 0 57 2 33 0 60 2 70 0 63 2 94 0 65 22 0 1 69 0 55 1 99 0 58 2 30 0 60 2 66 0 64 2 91 0...

Page 16: ...0 6 10 C TC PI TC PI TC PI TC PI TC PI 15 0 2 29 0 63 2 67 0 67 3 06 0 70 3 52 0 73 3 82 0 76 20 0 2 17 0 65 2 56 0 68 2 94 0 71 3 40 0 75 3 71 0 77 22 0 2 12 0 66 2 51 0 69 2 89 0 72 3 35 0 76 3 66 0...

Page 17: ...PI TC SHC PI Heating 50Hz 220 240V AFR 9 Indoor Outdoor temperature CWB EDB 10 5 0 6 10 C TC PI TC PI TC PI TC PI TC PI 3D055487 SYMBOLS AFR Air flow rate m3 min BF Bypass factor EWB Entering wet bul...

Page 18: ...6 10 C TC PI TC PI TC PI TC PI TC PI 15 0 2 69 0 81 3 14 0 85 3 60 0 89 4 14 0 94 4 50 0 97 20 0 2 55 0 83 3 01 0 87 3 46 0 91 4 00 0 96 4 36 0 99 22 0 2 50 0 84 2 95 0 88 3 40 0 92 3 94 0 97 4 31 1...

Page 19: ...PI TC SHC PI Heating 50Hz 220 240V AFR 10 Indoor Outdoor temperature CWB EDB 10 5 0 6 10 C TC PI TC PI TC PI TC PI TC PI 3D055489 SYMBOLS AFR Air flow rate m3 min BF Bypass factor EWB Entering wet bu...

Page 20: ...HC PI TC SHC PI Heating 50Hz 220 240V AFR 12 5 Indoor Outdoor temperature CWB EDB 10 5 0 6 10 C TC PI TC PI TC PI TC PI TC PI 3D057246 SYMBOLS AFR Air flow rate m3 min BF Bypass factor EWB Entering we...

Page 21: ...0 91 3 79 3 33 0 98 3 73 3 31 1 02 3 63 3 28 1 06 3 48 3 22 1 14 24 0 32 4 27 3 37 0 83 4 11 3 32 0 91 3 95 3 27 0 99 3 89 3 25 1 02 3 79 3 22 1 07 3 63 3 18 1 15 Indoor Outdoor temperature CWB EDB 1...

Page 22: ...00 1 42 5 58 3 92 1 54 5 49 3 88 1 59 5 35 3 83 1 66 5 11 3 75 1 78 24 0 32 6 27 3 98 1 30 6 04 3 90 1 42 5 81 3 83 1 55 5 72 3 80 1 60 5 58 3 75 1 67 5 34 3 68 1 79 Indoor Outdoor temperature CWB EDB...

Page 23: ...6 10 C TC PI TC PI TC PI TC PI TC PI 15 0 3 64 1 24 4 24 1 30 4 85 1 36 5 59 1 44 6 07 1 49 20 0 3 45 1 28 4 06 1 34 4 67 1 40 5 40 1 47 5 89 1 52 22 0 3 37 1 29 3 98 1 35 4 59 1 41 5 33 1 48 5 81 1 5...

Page 24: ...0 6 10 C TC PI TC PI TC PI TC PI TC PI 15 0 3 90 1 33 4 56 1 39 5 21 1 46 6 00 1 53 6 52 1 59 20 0 3 70 1 36 4 36 1 43 5 01 1 49 5 80 1 57 6 32 1 62 22 0 3 62 1 38 4 28 1 44 4 93 1 51 5 72 1 58 6 24 1...

Page 25: ...b temp C EDB Entering dry bulb temp C TC Total capacity kW SHC Sensible heating capacity kW PI Power input kW NOTES 1 Ratings shown are net capacities which include a deduction for indoor fan motor he...

Page 26: ...HC PI TC SHC PI Heating 50Hz 220 240V AFR 12 5 Indoor Outdoor temperature CWB EDB 10 5 0 6 10 C TC PI TC PI TC PI TC PI TC PI 3D057248 SYMBOLS AFR Air flow rate m3 min BF Bypass factor EWB Entering we...

Page 27: ...Of Removing Stop Valve Cover Gas Stop Valve 9 5 CuT Outdoor Air Thermistor Wall Height On Air Outlet Side Less Than 1200 MINIMUM SPACE FOR AIR PASSAGE RXS50G 4 Holes for anchor bolts M8 or M10 Drain...

Page 28: ...Outdoor Units R 410A RXS G2V1B Split Sky Air Outdoor Units 26 5 Dimensional drawing centre of gravity 5 2 Centre of gravity 3 24 5 RXS42G 4D059009B RXS50G The position of foundation bolt 4D051638L...

Page 29: ...6 4 CuT 6 4 CuT 7 0CuT Heat exchanger Thermistor 9 5 CuT 9 5 CuT 7 9 CuT 7 5 CuT Discharge pipe Thermistor Accumulator 4 0 x ID 2 OCuT RXS25 35G 6 4 CuT 6 4 CuT 9 5 CuT 9 5 CuT 9 5 CuT Propeller Fan...

Page 30: ...CuT 12 5 CuT Muffler With Filter 9 5 CuT 4 0 x ID 2 OCuT 7 5 CuT 7 5 CuT 3D059590A RXS50G 7 9 CuT 7 9 CuT 7 9 CuT 7 9 CuT 7 9 CuT 7 9 CuT 7 9 CuT 7 9 CuT 7 9 CuT 7 9 CuT 4 0 CuT 4 0 CuT 6 4 CuT 6 4 C...

Page 31: ...er Field wiring Indoor In case of cooling only type WIRING DIAGRAM In case of heat pump type RXS42G 3D059601 NOTES 1 Refer to purchasing specification AS303002 unless otherwise specified 2 This drawin...

Page 32: ...al Strip MRC W Magnetic Relay N Neutral M1F Fan Motor Y1E Electrionic Expansion Valve Coil R1T R3T Thermistor SW1 Forced Operation On Off SW SW1 L1R Reactor V2 V3 V5 V6 V 11 Varistor S2 S102 Connector...

Page 33: ...Octave band sound pressure level dB 0dB 0 0002 bar Approximate threshold hearing for continuous noise RXS20 25G HEATING Octave band center frequency Hz 1m 3D059593A NOTES 1 Operating conditons 50 Hz...

Page 34: ...itions Octave band sound pressure level dB 0dB 0 0002 bar Approximate threshold hearing for continuous noise RXS42G HEATING Octave band center frequency Hz 1m 3D059740A NOTES 1 Operating conditons 50...

Page 35: ...gh COOLING HEATING Indoor temp CWB Indoor temp CWB Outdoor temp CWB Outdoor temp CWB Continuous operation Continuous operation Pull down period RXS50G 3D028318M NOTES 1 The graphs are based on the fol...

Page 36: ......

Page 37: ...change without prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage in the broadest sense arising from or related to the use and or interpretation of this...

Reviews: